Fujitsu PRIMERGY RX2530 M1 Upgrade And Maintenance Manual page 101

Hide thumbs Also See for PRIMERGY RX2530 M1:
Table of Contents

Advertisement

Executing the fan test via ServerView Operations Manager
Ê Open the ServerView Operations Manager and log in.
Ê Under Administration select Server Configuration.
Ê In the hierarchy tree of the Server list tab, select the server to be configured.
Ê In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO....
In the left-hand section of the window, the Configuration tab is being
activated.
Ê In the navigation area of the Configuration tab, select Other Settings.
Ê Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Ê Click Save Page.
The fan test will be started at the specified time.
Ê After the fan test is complete, restore the time setting to its initial value and
click Save Page.
I
For more detailed information, refer to the "ServerView Operations
Manager" user guide.
For the Japanese market: Executing the fan test via Chassis ID Prom Tool
I
Please follow the instructions provided separately.
RX2530 M1
Upgrade and Maintenance Manual
Basic software procedures
101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy rx2530 m2

Table of Contents