Version: 16.12.2014 - Porsche 2015 911 GT3 Cup Technical Manual

Table of Contents

Advertisement

Further notes
While driving, the drain valve (4.8.1) should be open (pulled out) to ensure
that the air jacks are completely retracted.
A separate vent is accessible via a tappet in the drain valve for slowly
lowering a lifted vehicle. By pressing this tappet, the pneumatic system
can be vented in a controlled manner.
Never use mineral oil-based cleaning agents.
Porsche Motorsport recommends having an overhaul carried out by
Krontec after two years or 2,000 lifts.
Check the tightening torque of the grooved nut (air jack tightness) during
normal vehicle checks.
Tightening torque grooved nut, rear 45 ± 5 Nm (33 ± 3.7 ft-lb)
Tightening torque grooved nut, front 45 ± 5 Nm (33 ± 3.7 ft-lb)
Position of the rear air jack in the mounting tube (4.8.2)
If a loose or improperly mounted air jack is detected, it must be replaced
immediately as internal damage cannot be excluded.
For further safety regulations, please refer to the manufacturer's product description
(Krontec) addition 6.
KRONTEC
Maschinenbau GmbH
Pommernstraße 33
93073 Neutraubling
www.krontec.de

Version: 16.12.2014

Bodywork
4.8.1
42 mm
4.8.2
911 GT3 Cup (991)
MY 2015
187