Timeout Between Decodes
Timeout Between Decodes, Same Symbol
This option is used in continuous-on mode to prevent the beeper from continuously beeping
when a symbol is left in the scanner's field of view. It is programmable in 0.1 second
increments from 0.0 to 9.9 seconds. The recommended interval is 0.6 seconds.
Timeout Between Decodes, Different Symbol
Timeout Between Decodes, Different Symbol is used in continuous-on mode to prevent the
beeper from beeping when a different symbol appears in the scanner's field of view before
the timeout period between decodes expires. This is programmable in 0.1 second
increments from 0.0 to 9.9 seconds. The recommended value is 0.0 seconds.
Select the timeouts between decodes for the same or different symbols.
1. Scan the option bar code you wish to set.
2. Scan two numeric bar codes beginning on
desired interval, in 0.1 second increments.
3. If you make an error, or wish to change your selection, scan Cancel on page 132.