8.19
Removing and installing left footwell flap
control motor -V108-
Note
Mark the motor/flap connecting element on removal to avoid
interchange with the connecting elements of other control mo‐
tors.
In the event of the fault „Upper or lower limit value exceeded",
check the motor/flap connecting element. It must be properly
attached to the motor and there must not be any clearance
between the control motor mount and the connecting element.
Removing
– Switch off ignition.
– Remove the storage compartment beneath the dash panel on
the left. ⇒ General body repairs, interior; Rep. gr. 68
– Remove the centre console. ⇒ General body repairs, interior;
Rep. gr. 68
– Remove the left footwell vent (driver side).
– Carefully fold back the floor covering in the area of the control
motor.
– Screw out the bolts -A-.
– Mark the connector -B- to the control motor (to prevent inter‐
change with other identical connectors).
– Detach the control motor.
– Unplug the connector -B- from the control motor.
– Use 2 screwdrivers for example to carefully prise the cam plate
-C- off the control motor.
– Screw out the bolts -D-.
Installing
Install in reverse order, paying attention to the following.
– Attach the metal holder -E- to the control motor.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
8. Components for control and regulation of air conditioner located in passenger compartment
Audi A8 2003 ➤
Air conditioning - Edition 09.2010
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents