Parts - Procom MNSD2TPA Owner's Operation And Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

PARTS

MODEL MNSD2TPA
11
1
9
10
2
5
3
6
7
8
4
14
13
12
www.usaprocom.com
30
200218-01A

Hide quick links:

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MNSD2TPA and is the answer not in the manual?

Questions and answers

Donna Hutchison-Reynolds
March 4, 2025

Propane gas assembly specs and setup Instructions

1 comments:
Mr. Anderson
March 4, 2025

The ProCom MNSD2TPA heater operates with propane gas and has the following specifications:

- BTU Output: 10,000 BTU
- Regulator Pressure Setting: 10 inches of water column (c.a.)
- Gas Inlet Pressure:
- Maximum: 14 inches of water column (c.a.)
- Minimum: 11 inches of water column (c.a.)
- Ignition Type: Piezoelectric

For setup and installation:
- Ensure the heater is equipped for propane gas use.
- Follow the installation instructions in the manual.
- Do not attempt field conversion between gas types.
- Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Follow safety precautions, including avoiding the use of flammable vapors near the unit.

This answer is automatically generated

Subscribe to Our Youtube Channel

This manual is also suitable for:

Mnsd3tpa-bbMnsd3tpaMnsd5tpa-bbMnsd5tpa

Table of Contents