1. Do not place Propane/LP supply tank(s)
inside any structure. Propane/LP supply
tank(s) must be placed outdoors.
2. Heaters 10,000 Btu/Hr or more shall not
be installed in a bedroom or bathroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
8 and 9. If heater keeps shutting off, see
Troubleshooting, page 24.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
5. If heater shuts off, do not relight until you
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
6. Do not run heater:
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
4
SAFETY
7. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
8. Always run heater with control knob at
PILOT/IGN, LOW (1) or HIGH (5) locked
positions. Never set control knob between
locked positions. Poor combustion and
higher levels of carbon monoxide may
result.
9. Do not use heater if any part has been
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
10. Turn off and unplug heater and let cool
before servicing. Only a qualified service
person should service and repair heater.
11. Operating heater above elevations of
4,500 feet could cause pilot outage.
12. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lbs. capacity.
www.usaprocom.com
200218-01A

Hide quick links:

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MNSD2TPA and is the answer not in the manual?

Questions and answers

Donna Hutchison-Reynolds
March 4, 2025

Propane gas assembly specs and setup Instructions

1 comments:
Mr. Anderson
March 4, 2025

The ProCom MNSD2TPA heater operates with propane gas and has the following specifications:

- BTU Output: 10,000 BTU
- Regulator Pressure Setting: 10 inches of water column (c.a.)
- Gas Inlet Pressure:
- Maximum: 14 inches of water column (c.a.)
- Minimum: 11 inches of water column (c.a.)
- Ignition Type: Piezoelectric

For setup and installation:
- Ensure the heater is equipped for propane gas use.
- Follow the installation instructions in the manual.
- Do not attempt field conversion between gas types.
- Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Follow safety precautions, including avoiding the use of flammable vapors near the unit.

This answer is automatically generated

This manual is also suitable for:

Mnsd3tpa-bbMnsd3tpaMnsd5tpa-bbMnsd5tpa

Table of Contents