Procom MN200EPC Owner's Operation And Installation Manual

Infrared vent-free natural gas space heater

Advertisement

Quick Links

OW NE R ' S OPE RAT ION AND INSTA LLATION M ANUAL
MN200EPC MN200EHPC
MN300EPC MN300EHPC
WARNING
: Improper
adjustment, alteration, service or main-
ten an ce can cause injury or property
damage. Refer to this manual for correct
installation and operational procedures.
For assistance or additional information
consult a qualified installer, service agency,
or gas supplier.
WARNING
: This is an unvented gas-
fired heater. It uses air (oxygen) f r o m t h e
r o o m i n w h i ch i t i s installed. Provisions
for adequate combustion and ventilation
air must b e p ro vi d e d . Re fe r to Ai r F o r
Combustion and Ventilation section on
page 5 of this manual.
Continental Appliance Inc./US Office
5 Musick
4600 Highlands Parkway S.E.
Irvine
Suite# D/E
CA 92618
Smyrna GA 30080
Nanjing PRO-COM Electric Appliance Co.,Ltd.
#6 Chuangye Road,High New Tech.Zone,
Great Bridge Road North,Nanjing,210061,China.
TOLL FREE NUMBER: 1-877-886-5989
this manual is not followed exactly, a
fi r e o r exp l o si o n may resu l t causing
property damage, personal injury, or loss
of life.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electrical switch; do not
l Immediately call your gas supplier from a
installation,
l If you cannot reach your gas supplier, call
Installation and service must be performed by a
qu ali fie d ins tal ler, se rvi ce ag enc y o r g as
supplier.
This appliance may be installed in an
aftermarket* permanently located, manufac-
tured (mobile) home, where not prohib-
ited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU's
(.3KW's) of gas input per hour. Refer to page 4.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
INFRARED
WARNING
: If th e i nformati on in
use any phone in your building.
neighbor's phone. Follow the gas supplier's
instructions.
the fire department.
VE N T-F RE E
NATURAL GA S
SPACE H E AT E R
PR-MCL051-01-0506

Advertisement

Table of Contents
loading

Summary of Contents for Procom MN200EPC

  • Page 1 WHAT TO DO IF YOU SMELL GAS l Do not try to light any appliance. l Do not touch any electrical switch; do not MN200EPC MN200EHPC use any phone in your building. l Immediately call your gas supplier from a MN300EPC MN300EHPC neighbor’s phone.
  • Page 2: Table Of Contents

    Table of Contents Safety Information..................2 Product Features..................3 Local Codes....................3 Unpacking....................4 Air for Combustion and Ventilation............5 Installation....................7 Connecting to Gas Supply............... 9 Checking Gas Connections..............10 Operating Your Heater................11 Cleaning & Maintenance.................14 Replacement Parts..................16 Specifications..................16 Troubleshooting..................17 Parts List......................20 SAFETY INFORMATION Make certain you read and under- CARBON MONOXIDE POISONING...
  • Page 3: Product Features

    SAFETY INFORMATION l Immediately call your gas 11. Operating heater above WARNING: Do not use any supplier from a neighbor’s elevations of 4,500 feet could a c c e s s o r y n o t a p p r o v e d f o r phone.
  • Page 4: Unpacking

    PRODUCT FEATURES Touch Pad ON/OFF Switch Cabinet Top Burners Grill Guard Ignitor for Manual Override Control System Lower Front Panel Door Safety Pilot Control Knob for Manual Override Control System Figure1 Vent-Free Heater State of Massachusetts : The installation must be LOCAL CODES CONTINUED made by a licensed plumber or gas fitter in the Com-...
  • Page 5: Air For Combustion And Ventilation

    Confined and Unusually Tight Construction AIR FOR COMBUSTION The air that leaks around doors and Unconfined Space AND VENTILATION windows may provide enough fresh The National Fuel Gas Code ANSI air for combustion and ventilation. Z223.1 defines a confined space as WARNING: This heater shall However, in buildings of unusually a space whose volume is less than...
  • Page 6 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Example: Gas furnace Btu/Hr Gas water heater 40,000 Btu/Hr Vented gas heater Btu/Hr Vent free heater 18,000 Btu/Hr Gas Fireplace logs Btu/Hr Total 58,000...
  • Page 7: Installation

    INSTALLATION CAUTION: If you install the NOTICE: This heater is heater in a home garage tended for use as supplemental heater pilot and burner must heat. Use this heater along with be at least 18 inches above your primary heating system. Do floor.
  • Page 8 These two holes (see Figure 8). Floor are 16 inches apart from their Model MN200EPC MN200EHPC centers. Attach mounting bracket IMPORTANT: Do not to wall only in one of two ways: hammer...
  • Page 9: Connecting To Gas Supply

    *A CSA/AGA design-certified equip- CONNECTING TO GAS INSTALLATION " ment shutoff valve with 1/8 CONTINUED SUPPLY tap is an acceptable alternative to test gauge connection. Installing Bottom Bracket WARNING: A qualified service IMPORTANT : (See Figure 10) Check your gas person must connect heater to line pressure before connecting 1.
  • Page 10: Checking Gas Connections

    INSTALLATION Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.
  • Page 11: Operating Your Heater

    CHECKING GAS This appliance is equipped with 4. Wait five (5) minutes to clear out any an ignition device which CONNECTIONS gas. Then smell for gas, including automatically lights the pilot. Do near the floor. If you smell gas, CONTINUED not try to light the pilot by Pressure Testing Heater Gas STOP! Follow “B”...
  • Page 12 If the manual control knob points to OPERATING YOUR HEATER TO TURN OFF GAS TO continued HEATER ELECTRIC position, press in the control knob and turn counter clock- SETTING TIMER 1.Press the IGN/OFF button on the wise to OFF position. AUTO ON: With burner off, press touch pad.
  • Page 13 MANUAL OPERATING MANUAL LIGHTING INSTRUCTIONS PROCEDURE continued (Match Light) 9. When electric power is available 1. Remove lower front panel. Figure 16 - Correct Pilot Flame and electronic operation is 2. Follow steps 1 through 5 Pattern desired, turn clockwise under Manual Operatting OFF position for one minute.
  • Page 14: Cleaning & Maintenance

    CLEANING AND take out the control module. W hen To clean these parts we recommend MAINTENANCE installing , reverse the steps above. using compressed air no greater (See Figures 20, 23 and 24) than 30 PSl. Your local computer WARNING: Disconnect store, hardware store, or home center power before attempting any...
  • Page 15 Figure 23- (Model MN300EPC) Figure 24- Double Control System Diagram (Model MN200EHPC MN300EHPC)
  • Page 16: Replacement Parts

    FLOOR STAND MODEL: purchase date PF0920C warranty card Usually, we will ask you to return the defective part to the factory. SPECIFICATIONS MN300EPC(MN300EHPC) MN200EPC(MN200EHPC) 30,000 BTU/Hr 20,000 Natural Gas Only Gas Type Natural Gas Only Automatic(Automatic/Electronic) Ignition...
  • Page 17: Troubleshooting

    TROUBLESHOOTING WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately cal l your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 18 TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner injector is clogged 1. Clean burner injector (see Cleaning ODS/pilot has flame, but burner(s) Maintenance, Page14) does not light replace burner injector 2. Inlet gas pressure is too low Contact local natural gas company 3.
  • Page 19 TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Heater produces unwanted odors 1. Heater is burning vapors from Ventilate room. Stop using odor paint, hair spray, glues, etc. causing products while heater (See IMPORTANT statement is running at beginning of troubleshooting) 2.
  • Page 20 ILLUSTRATED PARTS BREAKDOWN MN200EPC...
  • Page 21: Parts List

    PARTS LIST This list contains replaceable parts for your heater. W hen ordering replacement parts, following the instructions listed under Replacement Part on page 15 of this MN200EPC manual. DESCRIPTION ML170EPC PART NO. MCL001-02 Cabinet Top MCL008-01 Cabinet Top Hinge...
  • Page 22 ILLUSTRATED PARTS BREAKDOWN MN200EHPC...
  • Page 23 PARTS LIST This list contains replaceable parts for your heater. W hen ordering replacement parts, following the instructions listed under Replacement Part on page 15 of this MN200EHPC manual. MN200EHPC DESCRIPTION PART NO. MCL006-02 Back panel MCL002-01 Left panel MCL003-01 Right panel MCL003-01B Door...
  • Page 24 ILLUSTRATED PARTS BREAKDOWN MN300EPC...
  • Page 25 PARTS LIST This list contains replaceable parts for your heater. W hen ordering replacement parts, following the instructions listed under Replacement Part on page 15 of this MN300EPC manual. MN300EHPC DESCRIPTION PART NO. MCL006-01 Back panel MCL002-01 Left panel MCL003-01 Right panel MCL003-01B Panel Door...
  • Page 26 ILLUSTRATED PARTS BREAKDOWN MN300EHPC...
  • Page 27 PARTS LIST This list contains replaceable parts for your heater. W hen ordering replacement parts, following the instructions listed under Replacement Part on page 15 of this MN300EHPC manual. MN300EHPC DESCRIPTION PART NO. MCL006-01 Back panel MCL002-01 Left panel MCL003-01 Right panel MCL003-01B Panel Door...

This manual is also suitable for:

Mn200ehpcMn300epcMn300ehpc

Table of Contents