Propane gas assembly specs and setup Instructions

1 comments:
Mr. Anderson
March 4, 2025

The ProCom MNSD2TPA heater operates with propane gas and has the following specifications:

- BTU Output: 10,000 BTU
- Regulator Pressure Setting: 10 inches of water column (c.a.)
- Gas Inlet Pressure:
- Maximum: 14 inches of water column (c.a.)
- Minimum: 11 inches of water column (c.a.)
- Ignition Type: Piezoelectric

For setup and installation:
- Ensure the heater is equipped for propane gas use.
- Follow the installation instructions in the manual.
- Do not attempt field conversion between gas types.
- Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Follow safety precautions, including avoiding the use of flammable vapors near the unit.