VENT-FREE GAS WALL HEATER
OWNER'S OPERATION AND
INSTALLATION MANUAL
BLUE FLAME
CSA/ANS
Z21.11.2 2019
Unvented
Room Heaters
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call
our customer service department at 1-866-573-0674, 8:00 am - 4:30 pm CST,
M(N,L)100HBG, M(N,L)100TBG
M(N,L)200HBG, M(N,L)200TBG
M(N,L)300HBG, M(N,L)300TBG
Monday through Friday or email contact@usaprocom.com
30,000 BTU/Hr
Model Shown
MODELS

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Procom MN100HBG

  • Page 1 VENT-FREE GAS WALL HEATER OWNER’S OPERATION AND INSTALLATION MANUAL BLUE FLAME 30,000 BTU/Hr Model Shown MODELS M(N,L)100HBG, M(N,L)100TBG CSA/ANS M(N,L)200HBG, M(N,L)200TBG Z21.11.2 2019 Unvented M(N,L)300HBG, M(N,L)300TBG Room Heaters WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Safety ............3 Operation ..........16 Qualified Installing Agency ......4 Inspecting Burners........20 Specifications ..........5 Care And Maintenance ......21 Product Features ........6 Troubleshooting ........22 Local Codes..........6 Technical Service........24 Preparing For Installation ......6 Replacement Parts ........
  • Page 3: Safety

    SAFETY IMPORTANT: Read this owner’s WARNING: Any change to manual carefully and completely this heater or its controls can before trying to assemble, op- be dangerous. erate, or service this heater. Improper use of this heater can WARNING: Do not use a cause serious injury or death blower insert, heat exchange from burns, fire, explosion,...
  • Page 4: Qualified Installing Agency

    SAFETY 1. Do not place Propane supply tank(s) in- 7. Before using furniture polish, wax, carpet side any structure. Propane supply tank(s) cleaner, or similar products, turn heater must be placed outdoors. off. If heated, the vapors from these prod- ucts may create a white powder residue 2.
  • Page 5: Specifications

    SPECIFICATIONS MODEL MN100HBG ML100HBG MN100TBG ML100TBG Ignition Piezo Piezo Piezo Piezo Gas Type Natural Propane Natural Propane Maximum BTU/Hr 10,000 10,000 10,000 10,000 Pressure Regulator Setting 4" W.C. 9" W.C. 4" W.C. 9" W.C. Max 10.5" Max 14" Max 10.5"...
  • Page 6: Product Features

    PRODUCT FEATURES SAFETY PILOT THERMOSTATIC CONTROL This heater has a pilot with an Oxygen Deple- (Thermostat Models Only) tion Sensing (ODS) safety shutoff system. The These heaters have a control valve with a ODS/pilot shuts off the heater if there is not thermostat sensing bulb.
  • Page 7: Unpacking

    UNPACKING 1. Remove heater from carton. 3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer 2. Remove all protective packaging applied where you bought heater. to heater for shipping WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combus- The following steps will help ensure that water tion.
  • Page 8 AIR FOR COMBUSTION AND VENTILATION VENTILATION AIR Ventilation Air From Inside Building Ventilation Air From Outdoors Provide extra fresh air by using ventilation This fresh air would come from an adjoining grills or ducts. You must provide two perma- unconfined space. When ventilating to an nent openings: one within 12"...
  • Page 9: Installation

    INSTALLATION IMPORTANT: Vent-free heaters add moisture NOTICE: This heater is intended to the air. Although this is beneficial, installing for use as supplemental heat. heater in rooms without enough ventilation air Use this heater along with your may cause mildew to form too much moisture. primary heating system.
  • Page 10 INSTALLATION REMOVING FRONT PANEL 1. Remove 4 screws securing front panel. 2. Carefully slide front panel forward. Screw Front Panel Figure 5 - Removing Front Panel INSTALLING THERMOSTAT SENSING BULB For 20,000 and 30,000 BTU/HR Heaters with Blower Installed Only 20,000 BTU/Hr Heaters 30,000 BTU/Hr Heaters 1.
  • Page 11 INSTALLATION FASTENING HEATER TO WALL Mounting Bracket " " The mounting bracket is located on back panel Min. of heater. It has been taped there for shipping. Remove mounting bracket from back panel. Methods For Attaching Mounting Only Insert Mounting 16"...
  • Page 12 INSTALLATION Attaching to Wall Anchor Method Installing Wall Spacers For attaching mounting bracket to hollow 1. Place heater on wall mounting bracket. walls (wall areas between studs) or solid walls 2. Mark screw locations on wall. (concrete or masonry): 3. Remove heater from mounting bracket. 1.
  • Page 13 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified ser- CAUTION: For propane gas, vice technician must connect Never connect heater directly to the gas supply. This heater heater to gas supply. Follow all requires an external regulator local codes. (not supplied). Install the external WARNING: This appliance regulator between the heater and requires a 3/8"...
  • Page 14 INSTALLATION Apply pipe joint sealant lightly to male threads. as shown in Figure 13. Pointing the vent down This will prevent excess sealant from going protects it from freezing rain or sleet. into pipe. Excess sealant in pipe could result Install sediment trap in supply line as shown in clogged heater valves.
  • Page 15 INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping WARNING: Never use an open and connections for leaks after flame to check for a leak. Apply a installing or servicing. Correct noncorrosive leak detection fluid all leaks at once. to all joints. If bubbles form, there is a leak.
  • Page 16: Operation

    INSTALLATION PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open equipment shutoff valve (see Fig- 5. Correct all leaks at once. ure 14, page 15). 6. Light heater (see Lighting Instructions on 2. Open gas supply tank valve. page 18). Check all other internal joints for leaks.
  • Page 17 OPERATION MANUAL CONTROL MODELS LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on 8. To select the desired heating level, partially page 16. press down the control knob slightly and turn counterclockwise . Release 2. Check that gas supply to heater is on. downward pressure on the knob while 3.
  • Page 18 OPERATION THERMOSTAT MODELS LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on 7. Keep control knob pressed in for 30 page 16. seconds after lighting pilot. After 30 seconds, release control knob. If control 2. Make sure equipment shutoff valve is fully knob does not pop up when released, open.
  • Page 19 OPERATION THERMOSTAT CONTROL OPERATION extinguishes (this point on the dial will The thermostatic control used on this change depending on room temperature), model differs from standard thermostats. then back counter-clockwise -just until You set standard thermostats to a specific the flame reignites. Leave the knob in temperature (such as 72 degrees);...
  • Page 20: Inspecting Burners

    INSPECTING BURNERS IMPORTANT: Owner’s should check pilot flame pattern and burner flame pattern often. Incorrect flame patterns indicate the need for cleaning (see Care and Maintenance, page 21) or service. WARNING: Only a qualified service person should service and repair heater. This includes maintenance requiring replacement or alteration of components.
  • Page 21: Care And Maintenance

    CARE AND MAINTENANCE WARNING: Turn off heater and let cool before servicing. CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service techni- cian.
  • Page 22: Troubleshooting

    TROUBLESHOOTING WARNING: If you smell gas: • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
  • Page 23 TROUBLESHOOTING Problem Possible Cause Corrective Action ODS/pilot lights but flame 1. Control knob is not fully 1. Press in control knob fully. goes out when control pressed in. knob is released. 2. Control knob is not pressed 2. After ODS/pilot lights, keep in long enough.
  • Page 24: Technical Service

    Ventilation require- ments, page 7. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact ProCom Heating, Inc. at 1-866-573-0674. When calling, please have your model and serial numbers of your heater ready. www.usaprocom.com 200307-01E...
  • Page 25: Replacement Parts

    REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. • Model and serial number of your heater If they can’t supply original replacement •...
  • Page 26: Parts

    PARTS MODELS MN100HBG, MN100TBG ML100HBG, ML100TBG Thermostat Valve Manual Valve www.usaprocom.com 200307-01E...
  • Page 27 PARTS MODELS MN100HBG, MN100TBG, ML100HBG, ML100TBG This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 25 of this manual. ITEM MN100HBG MN100TBG DESCRIPTION Back Body Panel 161132-01 161132-01...
  • Page 28 PARTS MODELS MN200HBG, ML200HBG, MN200TBG, ML200TBG MN300HBG, ML300HBG, MN300TBG, ML300TBG 20,000 BTU/Hr Model Shown Thermostat Valve Manual Valve www.usaprocom.com 200307-01E...
  • Page 29 PARTS MODELS MN200HBG, ML200HBG, MN200TBG, ML200TBG MN300HBG, ML300HBG, MN300TBG, ML300TBG This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 25 of this manual. ML200HBG ML300HBG MN200HBG MN300HBG ITEM MN200TBG ML200TBG MN300TBG...
  • Page 30 ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these acces- sories, contact ProCom Heating, Inc. at 1-866-573-0674 for information. EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff valve with 1/8" NPT tap. OPTIONAL FAN KIT - MGB100 Fan kit is optional for 20,000 &...
  • Page 31 NOTES ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ www.usaprocom.com 200307-01E...
  • Page 32: Warranty

    We make no other warranty, expressed or implied. NEW PRODUCTS Standard Warranty: ProCom Heating, Inc. warrants this product to be free from defects in materials and components for ONE (1) year from the date of first purchase, provided that the product has been properly installed by a qualified installer in accordance with all local codes and instructions furnished with the unit, operated and maintained in accordance with all applicable instructions.
  • Page 33 CALENTADOR DE PARED DE GAS SIN VENTILACIÓN MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO DEL PROPIETARIO Se muestra LLAMA AZUL el modelo de 30.000 BTU / h MODELOS CSA/ANS Z21.11.2 2019 M(N,L)100HBG, M(N,L)100TBG Calentadores M(N,L)200HBG, M(N,L)200TBG de habitación sin ventilación M(N,L)300HBG, M(N,L)300TBG ADVERTENCIA: si la información contenida en este manual no se sigue al pie de la letra, se puede producir un incendio o una explosión que podría ocasionar daños a...
  • Page 34 TABLA DE CONTENIDOS Seguridad ..........27 Instalación ..........33 Especificaciones ........29 Funcionamiento ........40 Identificación de producto......29 Inspección del Quemadores ....43 Agencia de Instalación Calificada.... 29 Cuidado y mantenimiento ......44 Características del Producto ....30 Solución de problemas ......45 Normas Locales........
  • Page 35: Seguridad

    SEGURIDAD IMPORTANTE: Lea este manual del Al gas propano se le agrega un agente con olor. El olor le ayuda a detectar las fugas de propietario cuidadosa y completa- gas. Sin embargo, el olor que se añade al gas mente antes de intentar ensamblar, puede desvanecerse.
  • Page 36 SEGURIDAD 8. Apague el calentador antes de usar puli- ADVERTENCIA: La pantalla dores de muebles, ceras, limpiadores de o protección contra incendios alfombras o productos parecidos. Si se diseñada para este aparato sin calientan, los vapores que se despren- den de estos productos pueden producir ventilación debe instalarse an- un residuo de polvo blanco dentro de la tes de la operación.
  • Page 37: Especificaciones

    ESPECIFICACIONES MODELO MN100HBG ML100HBG MN100TBG ML100TBG Encendido Piezo Piezo Piezo Piezo Tipo de gas Natural Propano Natural Propano Maximum BTU/Hr 10,000 10,000 10,000 10,000 Ajuste del regulador de presión: 4" W.C. 9" W.C. 4" W.C. 9" W.C. Max 10.5" Max 14"...
  • Page 38: Identificación De Producto

    IDENTIFICACIÓN DE PRODUCTO Botón de encendido Perilla de control Rejilla Quemador Gabinete del Panel calentador anterior Figura 1 - Calentador de gas sin ventilación AGENCIA DE INSTALACIÓN CALIFICADA La instalación y el remplazo de tuberías de a) Instalar, probar o remplazar tuberías de gas, de equipos o de accesorios para la gas o utilización de gas y la reparación y el mante-...
  • Page 39: Normas Locales

    NORMAS LOCALES Instale y use el calentador con cuidado. Siga Estado de Massachusetts: La instalación todas las normas locales. A falta de normas loca- la debe realizar un plomero o un instalador les, utilice la última edición del Código Nacional de gas con licencia para ejercer en el esta- de Gas Combustible, ANSI Z223.1/NFPA 54*.
  • Page 40: Aire Para Combustión Y Ventilación

    AIRE PARA COMBUSTIÓN Y VENTILACIÓN funcionamiento. Usted debe proporcionar aire ADVERTENCIA: Este calen- fresco adecuado para estos aparatos. Esto tador no se debe instalar en un asegurará una adecuada ventilación de los espacio reducido o excepcio- aparatos que queman combustible ventilados. nalmente hermético a menos ADVERTENCIA: Este calen- que se tomen las precauciones...
  • Page 41 AIRE PARA COMBUSTIÓN Y VENTILACIÓN AIRE PARA VENTILACIÓN Aire del interior de la construcción Aire del exterior para ventilación para ventilación Proporcione aire fresco adicional mediante Este aire fresco viene de un espacio adyacente el uso de rejillas o conductos de ventilación. no confinado.
  • Page 42: Instalación

    INSTALACIÓN AVISO: Este calentador está ADVERTENCIA: Nunca ins- diseñado para utilizarse como tale el calentador calefacción adicional. Use este • más de 6,000 BTU/h en un calentador junto con su sistema baño. No instalar calentadores de calefacción principal. No de más de 10,000 BTU/h en un instale este calentador como dormitorio.
  • Page 43 INSTALACIÓN DISTANCIA DE SEPARACIÓN DE EXTRACCIÓN DEL PANEL COMBUSTIBLES FRONTAL DEL CALENTADOR 1. Retire los dos tornillos cerca de las esqui- ADVERTENCIA: Mantenga nas inferiores del panel frontal inferior. las distancias mínimas como 2. Tire de la parte inferior del panel frontal se muestra en la Figura 4.
  • Page 44 INSTALACIÓN Cómo marcar las ubicaciones de 3. Inserte los tornillos de montaje en el los tornillos soporte y en las vigas de pared. 1. Fije el soporte de montaje a la pared con 4. Apriete los tornillos hasta que el soporte cinta, en el lugar donde estará...
  • Page 45 INSTALACIÓN Colocación del calentador en el el tornillo inferior de montaje en la viga soporte de montaje de pared, perfore orificios en los lugares 1. Localice las dos ranuras horizontales en marcados, con una broca de 9/64". el panel posterior del calentador (consulte 5.
  • Page 46 INSTALACIÓN CONEXIÓN AL SUMINISTRO DE GAS ADVERTENCIA: Una per- PRECAUCIÓN: Para gas sona de servicio capacitada propano, nunca conecte el calen- debe conectar el calentador al tador directamente al suministro suministro de gas. Siga todas de gas propano. Este calentador las normas locales.
  • Page 47 INSTALACIÓN Diámetros usuales de tubería de El instalador debe proveer un regulador externo. entrada El regulador externo reducirá la presión del Utilice tuberías de hierro negro de 3/8" o más gas entrante. Debe reducir la presión del gas grandes. La instalación debe incluir la válvula entrante de manera que esté...
  • Page 48 INSTALACIÓN Pruebas de presión del sistema de sea corrosivo. La formación de burbujas tuberías de suministro de gas indicará una fuga. 4. Repare todas las fugas inmediatamente. Presiones de prueba que exceden 3.5 kPa (1/2 PSI ) Válvula de gas 1.
  • Page 49: Funcionamiento

    FUNCIONAMIENTO POR SU SEGURIDAD, LEA ESTO ANTES DE ENCENDER EL CALENTADOR • Llame inmediatamente a su provee- ADVERTENCIA: No seguir dor de gas desde el teléfono de algún estas instrucciones al pie de la vecino. Siga las instrucciones del letra puede resultar en incen- proveedor de gas.
  • Page 50 FUNCIONAMIENTO piloto ligero con cerilla. Para encender el que el botón se trabe en la posición de piloto con el fósforo, vea el Procedimiento bloqueo. El quemador principal debe encenderse. No operar entre posiciones de encendido manual. 7. Mantenga presionado el botón de control bloqueadas.
  • Page 51 FUNCIONAMIENTO Hasta que se realicen las reparaciones, 8. Gire la perilla de control hacia la izquierda piloto ligero con cerilla. Para encender el hasta el nivel de calentamiento deseado. El quemador principal debe piloto con el fósforo, vea el Procedimiento de encendido manual, página 42.
  • Page 52: Inspección Del Quemadores

    INSPECCIÓN DEL QUEMADORES IMPORTANTE: El propietario debe revisar frecuentemente los patrones de la llama del piloto y de la llama del quemador. Patrones de llama incorrectos indican la necesidad de limpieza o servicio de mantenimiento (consulte Cuidado y mantenimiento, página 44). ADVERTENCIA: Sólo una persona de servicio capacitada debe repararlo o darle servicio.
  • Page 53: Cuidado Y Mantenimiento

    CUIDADO Y MANTENIMIENTO ADVERTENCIA: Apague el calentador y deje que se enfríe antes de darle mantenimiento. PRECAUCIÓN: Debe mantener limpias las áreas de control, el quemador y las vias de circulación de aire del calentador. Inspec- cione estas áreas del calentador antes de cada uso. Haga que una persona de servicio calificada inspeccione el calentador una vez al año.
  • Page 54: Solución De Problemas

    CUIDADO Y MANTENIMIENTO cuenta con aire comprimido, puede soplar a través de una pajilla o popote. GABINETE Electrodo del encendedor Termopar Conductos de aire Quemador Utilice una aspiradora o aire comprimido para de Piloto limpiarlos. Exterior • Utilice un paño humedecido con una mez- cla de agua y jabón suave.
  • Page 55 SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva Cuando se presiona el 1. Electrodo de encendido está 1. Reemplace el conjunto del piloto. botón del encendedor, no mal colocado. Electrodo de hay chispa en el piloto/ encendido está roto. 2. Remplace el cable del en- ODS.
  • Page 56 SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva El piloto/ODS se en- 1. La perilla de control no está 1. Presione la perilla de control ciende pero la llama se presionada completamente. completamente. extingue cuando la perilla 2. La perilla de control no se 2.
  • Page 57 SOLUCIÓN DE PROBLEMAS Problema Causa Posible Acción correctiva Llamas amarillas alta 1. No hay suficiente aire. 1. Revise el quemador en bus- durante la combustión ca de polvo y residuos. Si en el quemador. los hay, limpie el quemador (consulte Cuidado y mante- nimiento, en la página 44).
  • Page 58: Consejos Para Servicio

    Es posible que tenga preguntas adicionales sobre la instalación, el funcionamiento o la solución de problemas. De ser así, póngase en contacto con ProCom Heating, Inc. al 1-866-573-0674. Al llamar tenga a la mano los números de modelo y serie de su calentador.
  • Page 59: Piezas

    PIEZAS MODELOS MN100HBG, MN100TBG, ML100HBG, ML100TBG Thermostat Valve Manual Valve www.usaprocom.com 200307-01E...
  • Page 60 PIEZAS Esta lista contiene las piezas remplazables utilizadas en el calentador. Al hacer un pedido de piezas, siga las instrucciones listadas en Piezas de repuesto en la página 51 de este manual. ITEM MN100HBG MN100TBG DESCRIPTION Panel trasero del cuerpo...
  • Page 61 PARTS MODELOS MN200HBG, ML200HBG, MN200TBG, ML200TBG MN300HBG, ML300HBG, MN300TBG, ML300TBG 20,000 BTU/Hr Model Shown Thermostat Valve Manual Valve www.usaprocom.com 200307-01E...
  • Page 62 MODELOS MN200HBG, ML200HBG, MN200TBG, ML200TBG MN300HBG, ML300HBG, MN300TBG, ML300TBG This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 25 of this manual. ML200HBG ML300HBG MN200HBG MN300HBG ITEM MN200TBG ML200TBG MN300TBG ML300TBG...
  • Page 63: Piezas De Repuesto

    ACCESORIOS Adquiera estos accesorios con su distribuidor local. Si no pueden proporcionarle estos ac- cesorios, comuníquese ProCom Heating, Inc. al 1-866-573-0674 para obtener información. VÁLVULA DE INTERRUPCIÓN DE EQUIPOS Para todos los modelos. Válvula de interrupción de equi- pos con 1/2".
  • Page 64: Garantía

    ProCom Heating, Inc. No se autorizará ninguna devolución. Se proporcionarán piezas para reparar el producto.