Physical and Environmental Specifications

Table C-1 provides temperature and airflow information for minimum, typical, and maximum configurations
for the HP 9000 rp3410 and rp3440 servers. It also lists the server and rack weights and dimensions.
Table C-1
Physical and Environmental Specifications
Typical
Heat
Release
100-250
VAC
Min.
341 Watts
Config.
57.8
Max.
536 Watts
CFM
Config.
Typical
426 Watts
Config.
ASHRAE
Airflow cooling scheme (front to
Class 1
a.
Derate maximum dry bulb temperature 1 degree per 300 meters above 900 meters.
Appendix C
Condition
Airflow, at
Maximum
Airflow, Nominal
Ambient
degrees C
98.3
68.2
3
CFM
m
/hr
rear)
Weight
a
Server
Rack
Alone
115.94
38.6 lbs
49.0 lbs
3
(17.5 kg)
(22.2 kg)
m
/hr
Min./
One dual-core CPU, one power supply, 2 GB
Config.
DIMM, zero DVD, three HDDs.
Max.
Two dual-core CPUs, one power supply, 32 GB
Config.
DIMM, one DVD, three HDDs, one graphics card,
one SCSI card.
Typical
One dual-core CPU, one power supply, 6 GB
Config.
DIMM, one DVD, three HDDs, one graphics card,
one SCSI card.
Overall Server
(W x D x H)
Pede-
Pede-
Rack
stal
stal
W: 19.0 in
W: 11.6 in
56.3 lbs
(48.3 cm)
(29.5 cm)
(25.5 kg)
D: 26.8 in
D: 26.6 in
(67.9 cm)
(67.5 cm)
H: 3.4 in
H: 19.5 in
(8.6 cm)
(49.4 cm)