Removing and Replacing Components
Removing and Replacing the PCI Card Cage
Step 6. Verify the battery replacement and operation by using the system utilities. (See the Utilities
chapter or the HP Integrity and HP 9000 iLO MP Operations Guide for additional information.)
•
Use the iLO MP commands to verify operation.
•
Use the BCH commands to verify operation.
Step 7. You must reset the system time and date using the BCH DATE command. Once you have set the
time, turn the server off, unplug the power cord, and wait for a minute before turning it back on.
Execute the DATE command again. If the time and date are now correct, you have installed the
battery correctly.
Step 8. Reset the LAN configuration settings, boot settings, or any other system settings.
Removing and Replacing the PCI Card Cage
PCI cards are installed in a removable PCI card cage. This section explains how to access the PCI card cage,
as well as how to remove and install PCI cards.
Removing the PCI Card Cage
To remove the PCI card cage from the server, follow these steps:
Ensure that the server is powered off and all power sources have been disconnected
WARNING
from the server before removing or replacing a PCI card cage.
Voltages are present at various locations within the server whenever an ac power
source is connected. This voltage is present even when the main power switch is in
the off position.
Failure to observe this warning can result in personal injury or damage to
equipment.
Step 1. Remove the top cover. (See "Removing and Replacing Server Covers and Bezel" on page 151.)
Step 2. Disconnect cables from the PCI cards.
200
Chapter 6