Updating from Local Computer

Update the firmware from the computer connected in Parallel. The machine has to be in the serviceman mode to perform
the updating of the firmware. (Refer to 7.1.1 "Before Updating the Firmware")
1.
Set to "Standard (Output Only), EPP , EPC" at Parallel Port setting of BIOS on your computer if not.
2.
Copy the update file to the local hard disk of the computer if it is in other devices.
3.
Start DOS prompt.
4.
Change the directory to where the copy of the update file is located, and then enter "copy /b xxx.up lpt1:" at DOS
prompt. Updating firmware is start and the message "F-ROM updating" is displayed on Control Panel.
xxx is the update file name.
5.
The message "F-ROM update completed" is displayed on Control Panel after updating the firmware is completed.
6.
Perform the Printer Reset, or turn the machine OFF, then ON to restart it.
SUPPLEMENT:
The updating results can be confirmed by the Setting List printed out at WebPage or
Control Panel.
After the updating is completed and performing the Printer Reset, or turning the power
OFF then ON, the "Printer error (Error code: P52)" error may occur.
Please restart the machine again if this error occurs.