Specifi Cations - Valor 1400IN Installation & Owner's Manual

H6 series dv zc gas fireplaces
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or the Natural Gas and Propane
Installation Code CAN/CGA-B149. Only qualifi ed
licensed or trained personnel should install this
appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
20
Specifi cations
*High Altitude Installations
I nput ratings are shown in BTU
per hour and are certifi ed without
deration for elevations up to
4,500 feet (1,370 m) above sea
level.
For elevations above 4,500 feet
(1,370 m) in USA, installations
must be in accordance with the current ANSI Z223.1
and/or local codes having jurisdiction. Heating value
of gas in some areas is reduced to compensate for
elevation—consult your local gas utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
Supply Gas
Heater engine 1400IN is used with natural gas.
Heater engine 1400IP is used with propane gas.
The supply pressure must be between the limits shown
in the Ratings section.
1400IN
1400IP
The supply connection is 3/8" NPT male and located on
Natural
Propane
the right hand side of the fi rebox. A shut-off valve (not
supplied) is required on the supply line to isolate the
0-4,500 feet*
unit during service. See Supply Gas Installation section
36,000
30,000
for details.
19,000
15,000
4.0"
9.0"
Conversion Kits
5.0"
11.0
The 1400 is supplied as natural gas or propane gas
10.0"
14.0
and is fi eld convertible between fuels. See instructions
1000
360
packaged with the conversion kits for further
51
30
information.
220
125
Electrical
The 1400 is designed to run on battery power and does
not require an electrical power source to operate as a
heater. However, it requires electrical power to operate
optional 1195CFK Circulating Fan Kit, 1270RBK
Remote Blower Kit or GV60PAK Power Adapter.
X