Valor 1700IN Installation & Owner's Manual

Dv zc gas fireplace l2 series

Advertisement

1700IN (NG) & 1700IP (LPG)
WARNING
!
A barrier designed to reduce the risk of burns from the hot viewing
glass is provided with this appliance and shall be installed
for the protection of children and other at-risk individuals.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other
fl ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light the appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fi re department.
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
4003743-03
©2013, Miles Industries Ltd.
L2 S
DV ZC Gas Fireplace
Installation & Owner's Manual
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Miles Industries Ltd.
www.valorfi replaces.com
ERIES
Please read this manual
BEFORE installing and
operating this appliance.
This manual contains instructions to install the
ENGINE ONLY. A trim kit is REQUIRED to
complete the installation. A barrier screen is
provided with the trim kit. Refer to the manual
supplied with the trim for installation.
This appliance may be installed in an
after-market permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certifi ed kit is used.
This appliance is a domestic room-heating
appliance. It must not be used for any other
purposes such as drying clothes, etc.
This appliance is suitable for installation in a
bedroom or bed sitting room.
Ce guide est disponible en français sur demande.
I N S TA L L E R
L e a v e t h i s m a n u a l
w i t h t h e a p p l i a n c e .
C O N S U M E R
R e t a i n t h i s m a n u a l
f o r f u t u r e r e f e r e n c e .

Advertisement

Table of Contents
loading

Summary of Contents for Valor 1700IN

  • Page 1 L2 S ERIES DV ZC Gas Fireplace 1700IN (NG) & 1700IP (LPG) Installation & Owner’s Manual WARNING I N S TA L L E R L e a v e t h i s m a n u a l HOT GLASS WILL w i t h t h e a p p l i a n c e .
  • Page 2: Table Of Contents

    Designed and Manufactured by / for Miles Industries Ltd. 190–2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com © Copyright Miles Industries Ltd., 2013...
  • Page 3: Safety Precautions

    Safety Precautions READ and UNDERSTAND all instructions carefully This unit MUST be used with a vent system as before starting the installation. FAILURE TO FOLLOW described in this installation manual. NO OTHER vent these installation instructions may result in possible fi re system or components MAY BE USED.
  • Page 4: Safety And Your Fireplace

    Child Safety Precautions and Recommendations, • A physical barrier is strongly recommended if there are young Parts of your Valor Fireplace become • children, or at-risk individuals in the extremely hot while in operation. house. Install an approved after- The glass viewing window •...
  • Page 5: Owner's Information

    For purchasing a Valor by Miles Industries. Your new EXTREMELY HOT!!! radiant gas heater is a technical appliance that must be installed by a qualifi ed dealer. Each Valor fi replace • READ the SAFETY information on pages is fully tested during the production process for your 3 and 4 of this manual BEFORE operating safety and comfort.
  • Page 6 OWNER’S Owner’s Information INFORMATION Cleaning To remove the window for cleaning: 1. Remove the barrier screen. WARNING a) 1755 1” trim: slide the screen up, unhook the bottom tabs and disengage the top tabs. DO NOT TOUCH THE GLASS WHILE IT IS HOT! Let the fi...
  • Page 7 OWNER’S Owner’s Information INFORMATION Checks WARNING A periodic check of the pilot and burner fl ames should CHOKING HAZARD! Ensure that the fi replace be made. Check after the fi re has been on for at least area is clear of fi re glass or vermiculite particles as 30 minutes.
  • Page 8 OWNER’S Owner’s Information INFORMATION 3. Remove and disconnect the battery box. Batteries Do not pull the box out by the wire. WARNING 4. Remove the screw and slide the cover off. DO NOT ATTEMPT TO CHANGE THE BATTER- IES WHILE THE FIREPLACE IS STILL HOT! Let the fi...
  • Page 9 OWNER’S Owner’s Information INFORMATION Servicing How to Ensure Your Fireplace Cannot If any attention is required for your appliance, contact Be Turned ON Inadvertently your supplier quoting the model number. It will be You can use one of the two following methods to helpful if the appliance’s serial number can also ensure that your fi...
  • Page 10: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION NOTE: Before using the remote control system for IMPORTANT: BEFORE YOU BEGIN, please note that the fi rst time, the receiver and the handset must be on this system, the settings of time, temperature and synchronized.
  • Page 11 OWNER’S Remote Control Operation INFORMATION • Press and hold (small fl ame) MODES OF OPERATION button to decrease fl ame height or • Briefl y pressing the SET button to set the appliance at pilot fl ame. changes the mode of operation in •...
  • Page 12 OWNER’S Remote Control Operation INFORMATION SETTING THE ON / OFF TEMPERATURES SETTING THE “NIGHTTIME SETBACK” SETTING THE “DAYTIME” TEMPERATURE TEMPERATURE (sun), 23ºC / 74ºF (moon), “ Default Settings: Default Settings: ” (OFF) TEMP T E M P • Briefl y press SET button to scroll to •...
  • Page 13 OWNER’S Remote Control Operation INFORMATION SETTING PROGRAM TIMERS SETTING P1 OFF TIME • You can program two periods of time between 12:00 • Briefl y press SET button to scroll am and 11:50 pm in each 24-hour cycle. to TIMER (moon) while the •...
  • Page 14 OWNER’S Remote Control Operation INFORMATION Timer Programming Example (default temperatures shown) 4:00 p.m.— 6:00 a.m.— 8:00 a.m.— 10:00 p.m.— ☼ 6:00 a.m.— ☼ ☼ ☽ ☽ Start time Start time End time End time Start time ☼ ☼ ☽ ☽ Set temp 40˚F Set temp...
  • Page 15: Wall Switch Operation

    OWNER’S Wall Switch Operation INFORMATION The Wall Switch can be used to TO ADJUST FLAME HEIGHT control your fi replace. You can turn the pilot on or off and you can • Press and hold large fl ame increase or decrease the fl ame button to gradually increase height.
  • Page 16: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions exactly.
  • Page 17: Commonwealth Of Massachusetts

    QUALIFIED Commonwealth of Massachusetts INSTALLER 3. SIGNAGE. A metal or plastic identifi cation plate State of Massachusetts Carbon Monoxide shall be permanently mounted to the exterior of the Detector/Vent Terminal Signage building at a minimum height of eight (8) feet above Requirements grade directly in line with the exhaust vent terminal for For all side wall horizontally vented gas fueled...
  • Page 18 QUALIFIED Commonwealth of Massachusetts INSTALLER (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the fl ue gases, but identifi...
  • Page 19: Specifi Cations

    Standard for Vented Gas Fireplace Heaters for use in Supply Gas Canada and USA, and to CGA 2.17-91 High Altitude Heater engine 1700IN is used with natural gas. Standard in Canada. This appliance is for direct vent Heater engine 1700IP is used with propane gas.
  • Page 20: Overview

    QUALIFIED Overview INSTALLER Fire On/Off Wall Switch Mantel—See Mantel & Hearth Clearances (20-foot wire length) (supplied) Framing—See Framing Requirements Remote Handset Supplied as Wall Holder vertical outlet, fi eld 1/2 inch thick Optional Decorative convertible to S urrou non-combustible Light Dimmer horizontal outlet.
  • Page 21: Dimensions & Location

    QUALIFIED Dimensions & Location INSTALLER Dimensions 57.3/4” (1467 mm) 52” (1321 mm) Center Line Heat shield required for rear vent outlet 18-5/8” applications (473 mm) 15-3/16” Top View 6-5/8” dia. (386 6 mm) Venting field- convertible from top to Zero Clearance Header rear outlet Stand-Offs...
  • Page 22: Mantel & Hearth Clearances

    QUALIFIED Mantel & Hearth Clearances INSTALLER Combustible Mantel—Left Side View Ceiling Mantel Projection (from Face of Cement Board) 0 2” 4” 6” 8” 10” 12” 44” Mantel 42” Height (from 40” Bottom 38” of Unit) Face of 1/2” thick non-combustible cement board 23-7/8”...
  • Page 23 QUALIFIED Mantel & Hearth Clearances INSTALLER Combustible Sidewall / Mantel Leg—Top View FIREPLACE Face of Finished Wall Fireplace Opening 49-11/16” Wall Min. 4” to wall or combustible mantel leg...
  • Page 24: Framing Requirements

    QUALIFIED Framing Requirements INSTALLER Framing Dimensions NOTE: Height of cavity may be affected by vent configuration - see page 26 1/2” thick non-combustible cement board required above, on each side and below Between underside engine opening (NOT supplied) of header and bottom of firebox NOTE: This unit requires a solid platform to support it.
  • Page 25 QUALIFIED Framing Requirements INSTALLER Framing with Partial Shelf—Top Outlet 15-3/16” (386 mm) Approx. 10-3/4” (274 mm) from back surface of wall finish to front surface of appliance case w/no vent offset 1/2” thick Min. 1” non-combustible (25.4 mm) Cement Board clearance to combustibles around...
  • Page 26 QUALIFIED Framing Requirements INSTALLER Venting Considerations—Vertical Takeoff Notes—ALL venting considerations • Dimensions of venting are based on using Dura-Vent elbows. Elbow curve radius dimensions will vary when using 12” pipe section other brands. In general, other brands have slightly bigger radius. •...
  • Page 27: Venting

    QUALIFIED Venting INSTALLER Top or Rear Outlet Framing Vent in Combustible Walls & This unit is supplied with a top vent outlet which can Ceilings be fi eld-converted to a rear vent outlet. See Appliance When penetrating through combustible walls and Preparation section for more information.
  • Page 28: Co-Axial Venting

    QUALIFIED Co-axial Venting INSTALLER Typical Co-axial Venting Components HORIZONTAL TERMINATION 2-PIECE WALL THIMBLE VERTICAL TERMINATION 90˚ ELBOW PIPE STORM LENGTH COLLAR PIPE LENGTH FLASHING 90˚ ELBOW ATTIC INSULATION SHIELD HORIZONTAL TERMINATION ATTIC FIRESTOP CEILING FIRESTOP 2-PIECE Rear Vent WALL THIMBLE PIPE LENGTH PIPE LENGTH...
  • Page 29 QUALIFIED Co-axial Venting INSTALLER be used. Excludes the 45 degrees take-off elbow How to Read the Venting Chart shipped with the appliance. The chart below applies to co-axial roof or wall 6. Each 90 degrees elbow installed on the horizontal termination.
  • Page 30 QUALIFIED Co-axial Venting INSTALLER Restrictor The restrictor is located in the roof of the fi rebox hidden above the top liner panel. Adjust the restrictor before installation of the top liner panel. Should subsequent adjustment be required, you will need to remove the top liner panel—see page 41.
  • Page 31: Vent Termination

    QUALIFIED Co-axial Venting INSTALLER Vent Termination • The vent terminal must be located on an outside of the airfl ow or a safety hazard. Local codes or wall or through the roof. regulations may require greater clearances. • This direct vent appliance is designed to operate •...
  • Page 32: Co-Linear Venting

    QUALIFIED Co-axial Venting INSTALLER Vertical Vent Termination Overhang should not extend beyond vent if within 48” of Horizontal termination cap overhang Roof Minimum Pitch "H" (feet) Flat to 7/12 Termination Min. 24” Over 7/12 to (unvented soffit) 1.5' 8/12 Min. 36” Vertical Min.
  • Page 33 QUALIFIED Co-linear Venting INSTALLER Dimensions with co-linear adapter Dimensions shown are with Dura-Vent co-linear adapter. Other manufacturers’ adapters may vary. 19-5/8” (498 mm) 12” (305 mm) 23-3/8” (594 mm) Linear top outlet with Linear rear outlet with co-linear adapter co-linear adapter Co-linear terminal confi...
  • Page 34: Installation Planning

    QUALIFIED Installation Planning INSTALLER Installer—READ THIS FIRST Only qualifi ed licensed or trained personnel 6. Remove the window of the appliance. should install this appliance. 7. Install the venting system and tape vent pipe joints. 8. Position the restrictor. 1. YOU NEED TO KNOW FROM THE HOMEOWNER: 9.
  • Page 35 QUALIFIED Appliance Preparation INSTALLER 2. Swivel the collar and install as a rear outlet (6 screws). 5. Remove the 4 screws retaining the engine to its Reinstall heat pallet. shield to top of 6. Taking great care not to appliance (3 screws) cut your hands on the sheet metal edges, lift the...
  • Page 36 QUALIFIED Appliance Preparation INSTALLER Wall Finishing Non-combustible cement board Gypsum board The L2 Linear fi replace requires a 1/2” Min. 60” up to perimeter (13 mm) thick non-combustible cement (1524 mm) of cement board board to be used as a wall surface 50”...
  • Page 37: Window Removal

    QUALIFIED Appliance Preparation INSTALLER • Always pre-drill screw holes through cement board Cracking and use screws with self-milling head. If a clean fi nish with no tile, etc. is desired, joints in • Always use tape over joints. the cement board and the transition to gypsum board will require special attention if future cracking is to be •...
  • Page 38: Electrical Wiring (For Optional Accessories)

    QUALIFIED Electrical Wiring (for optional accessories) INSTALLER This section provides information to install the electric 2. Provide a steel surface mount electrical utility box pre-wiring required for use with the 1595CFK Circulat- (Iberville BC 1110 or equivalent), thread cable ing Fan Kit and/or the 1565LLK Lighting Kit. through knock-out in the end of box and through the cable clamp locking ring (if used).
  • Page 39: Supply Gas Installation

    QUALIFIED Electrical Wiring (for optional accessories) INSTALLER 7. Pull the excess cable back through the cable clamp and tighten the locking ring to the cable clamp. Alternate clamp without locking ring may be used - ensure the proper clamp is used for the type of cable used.
  • Page 40 QUALIFIED Supply Gas Installation INSTALLER Pressure test the supply line for leaks. The appliance and its individual shut-off valve must be Window Flexible disconnected from the gas supply piping system during connector any pressure testing of that system at test pressures in supplied excess of 1/2 psig (3.5 kPa).
  • Page 41 QUALIFIED Liners Installation INSTALLER The ceramic liners install in the manner outline below. Place the panel’s right section on the ledge above the ports of the rear of the fi rebox. The section sits For the enamel liners, an infi ll set will be needed on the ledge behind the tabs, with its plain edge on with less than 3’-0”...
  • Page 42: Liners Installation

    QUALIFIED Liners Installation INSTALLER 6. Place rear panel’s centre section on the ledge 10. Carefully lift, slide and position top panel on to left behind the tabs, slide it to the right so that its side and rear panel. stepped edge fi ts into the stepped edge of the rear panel’s right section.
  • Page 43: Long Beach Driftwood Kit Installation

    QUALIFIED Long Beach Driftwood Kit Installation INSTALLER 3. Fill a small container with the equivalent of Material required approximately 3 cups (750 ml) of vermiculite from • Middle platform brackets (supplied with appliance) the bag supplied. • Vermiculite platform (supplied with appliance) •...
  • Page 44 QUALIFIED Long Beach Driftwood Kit Installation INSTALLER 4. Place the right rear log as indicated. Pivot tail end to Logs and rocks just cover small hole located in platform. Each log has pegs to help you locate them on the platform.
  • Page 45: Murano Glass Fire Installation

    Bottom IMPORTANT: For safety reasons, use only the fi re glass provided with your Valor fi replace or the tem- pered crushed fi re glass brands American Fireglass™ or fi regear. The use of any other fi re glass products...
  • Page 46 QUALIFIED Murano Glass Fire Installation INSTALLER 2. Install the sheet metal platform on top of the 4. Mix the black and blue fi re glass together. brackets as indicated. The edge of the burner 5. Fill a small container with approximately 3 cups protrudes above the platform.
  • Page 47: Window Refi Tting

    QUALIFIED Window Refi tting INSTALLER 1. To refi t the window, place it in its bottom railing and push its top against the fi rebox. 2. While you hold it, pull the side levers back into the window brackets on each side. Window frame IMPORTANT: To ensure a safe operation, verify that the levers are hooked properly to the...
  • Page 48: Wall Switch Kit Installation (Required)

    QUALIFIED Wall Switch Kit Installation (required) INSTALLER WARNING F O R SAFET Y PURPO SE, t he wa ll s w i t c h F OR SAF ET Y PU RP OS E, t he wa ll s w i tc h k it prov id ed wit h th is a pplia n c e M U S T k it p r o vi ded wit h th is a pplia n c e M UST BE I NS TALLE D.
  • Page 49: Remote Control Initial Set-Up

    QUALIFIED Wall Switch Kit Installation INSTALLER 7. Reconnect the ignition wire to the receiver if it was 12. Slide the carrier towards previously removed. the right hand side so that the battery box goes IMPORTANT: Make sure the ignition wire DOES outside of the appliance NOT TOUCH the receiver’s antenna.
  • Page 50: Operation Check & Aeration Settings Adjustment

    QUALIFIED Operation Check & Aeration Settings Adjustment INSTALLER adjustment should be determined only by operating the Operation Check appliance with the fuel bed and window installed. Turn the fi replace fl ame up and down using the remote control to confi rm that the full range of inputs Increasing aeration will cause the fl...
  • Page 51: Remote Control Handset Wall Holder Installation

    QUALIFIED Remote Control Handset Wall Holder Installation INSTALLER The remote control kit for this fi replace comes complete with a wall-mounted holder. This Packing Contents: Alternative 2 Alternative 3 holder is not required in all installations but 1 Wall Bracket A is provided as an optional feature for those 2 Screws B 1 Screw C...
  • Page 52: Wiring Diagram

    QUALIFIED Wiring Diagram INSTALLER Wall Switch Kit Connector Remote Battery Box 4 AA Batteries GV60 Wiring Diagram...
  • Page 53: Approved Venting Components

    QUALIFIED Approved Venting Components INSTALLER Approved Direct Vent Suppliers for Valor Models 1200, 1300, 1500, 1600 and 1700 Venting Parts Code / availability by Manufacturer Venting Parts Description Co-axial Kit, 26” long — — — — — — — Standard Co-axial...
  • Page 54 QUALIFIED Approved Venting Components INSTALLER Venting Parts Code / availability by Manufacturer Venting Parts Description Galvanized 46DVA-06 4DT-06 TC-4DL6 SV4L6 6” long — — — Black 46DVA-06B 4DT-06(B) TC-4DL6B SV4LB6 Galvanized 7” long — — — — — — Black 4D7B Galvanized 46DVA-09...
  • Page 55: Warranty

    OWNER’S Warranty INFORMATION If you have a problem with this unit, please contact your dealer or supplier immediately. Under no circumstances should you attempt to service the unit in any way by yourself. The warranties in paragraphs 1 and 2 are provided only to the fi rst purchaser/user of this unit, are not transferable and are subject to the conditions and limitations in paragraphs 3, 4 and 5.
  • Page 56: Spare Parts

    OWNER’S Spare Parts INFORMATION Part Part Code Description Code Description Number Number Heat shield 4003049 Thermocouple interrupter 4001037 45 degrees fl anged elbow 0945M Pipe s/s fl ex 4000345 Elbow gasket 4002999 Handset wall holder 9000008 Top stand-offs (2) 4002985 Handset G6R H3T5-ZV (BJ) 4001910 Restrictor plate...
  • Page 57 OWNER’S Spare Parts INFORMATION Part Code Description Number LH front log 4002967 Center cross log 4003721 RH rear log 4003928 RH Cross log 4003929 Brown beach pebble 4003082 Grey beach pebble (2) 4003083 Small grey beach pebble 4003086 White beach pebble (2) 4003084 Black beach pebble (2) 4003085...
  • Page 58 OWNER’S Spare Parts INFORMATION 15a, 15b 25-26 20-24 28a, 28b 37a, 37b...
  • Page 59 Thank You ... For purchasing a Valor by Miles Industries. Your new radiant gas heater is a technical appliance that must be installed by a qualifi ed installer. Please fi ll in the information below. The information provided will be used for customer records only.
  • Page 60 Tape Shut Fold here Postage needed Miles Industries Ltd. 190 - 2255 Dollarton Highway North Vancouver, BC V7H 3B1 Canada Online Warranty registration at www.valorfi replaces.com Thank you for choosing a Valor Product...

This manual is also suitable for:

1700ip

Table of Contents