SDP-Eco1630 III USERS MANUAL
The filter must always be installed. If you attempt to operate this
machine without a filter, the processing chemical supply pipe will
Caution
become clogged and seriously affect subsequent results.
5) Return the processing chemical tank to its original position and replace
its upper cover.
Since the heater is attached to the tank's upper cover, be sure the
cover is properly seated into the top of the tank to prevent the heater
Caution
from overheating.
Supply hose
Processing
Processing
chemical supply
chemical supply
pipe (rinse water)
pipe (SLM-EST)
Supply hose
Filter
Supply hose
Processing
chemical supply
pipe (SLM-EAC)
Processing chemical
supply pipe
- 54 -
2) Remove the filter installed in the
processing chemical tank.
3) Wash the filter and processing
chemical tank with water.
4) Re-install the filter in the
processing chemical tank.
Note
Pull the cylindrical filter down
over the filter attachment
section in the processing
chemical tank.
Cleaning the processing chemical
supply pipe
Note
Always clean the processing
chemical supply pipe when
you replace the processing
chemical every three months.
1) Remove the processing chemical
supply pipes (for SLM-EAC,
rinse water, and SLM-EST).
2) Remove the supply hose from the
processing chemical supply pipe.
3) Clean the processing chemical
supply pipe.