Rotax 912 Series Maintenance Manual page 80

Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

Exceeding
Table 2.
over 180 °C
Excess temperature of over 180 °C (356 °F) and/or for longer than 30 min.
Step
1
2
3
4
5
Effectivity: 912 Series
Edition 3 / Rev. 1
BRP-Powertrain
MAINTENANCE MANUAL
The whole cooling system must be inspected, repaired or overhauled in
accordance with the BRP-Powertrain instructions for continued airworthi-
ness.
Inspect all further systems for correct functioning.
Carry out detailed inspection of the affected engine components.
Check compression by carrying out a differential pressure check.
All cylinder heads and cylinders must be removed and subjected to a de-
tailed check including hardness testing.
See chap. 72-00-00 in the Heavy Maintenance Manual.
Procedure
05-50-00
page 14
January 01/2013