Step
1
2
3
4
5
6
Graphic
Option 4
Fig. 20
Effectivity: 912 Series
Edition 3 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Install the vacuum gauge.
Clamp the tube (2) with hose clamping pliers (1). Observe the position! Do not
remove the compensation tube (3).
Unscrew the screw (4).
Install a hose nipple M6 (5) with sealing ring or O-ring (6).
After synchronization remove the hose nipple M6 (5).
Secure screw M6x6 (4) with a new gasket (6) and LOCTITE 221.
3
2
Part
1
Clamping pliers
2
Tube
3
Compensation tube
4
Screw
5
Hose nipple
6
Sealing ring
Option 4
Procedure
1
5
4
Function
6
08661
12-20-00
page 37
September 01/2012