Rotax 912 Series Maintenance Manual page 72

Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

Measurement
Repeat the measurement several times to get a stable value.
The breakaway torque is calculated on the basis of the force (F) measured
in N and the length of the lever arm (L) used at the normal distance from it
in m (N x m = Nm).
Obtained value
The value determined must be between 600 and 800 Nm (442 and
590 ft.lb.).
If the value is greater or smaller than the limit value, the overload clutch
must be inspected, repaired or overhauled in accordance with the BRP-
Powertrain instructions for continued airworthiness.
Step
4
Effectivity: 912 Series
Edition 3 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Do not exceed 800 Nm (590 ft.lb) otherwise gearbox
WARNUNG
NOTICE
damage can occur.
Release the crankshaft, see chap. 12-20-00 section: 7).
Procedure
05-50-00
September 01/2012
page 6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents