Step
13
14
Engine oil and
coolant
Replenish engine oil and coolant as required once engine has cooled
down.
Oil filter
Check of leaks
Inspect the engine for oil, fuel or coolant leaks and repair as necessary.
Effectivity: 912 Series
Edition 3 / Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Shut engine down.
NOTE:
On switching off the engine switch off ignition and withdraw the
ignition key.
Inspect rotary seal for leakage.
NOTE:
Due to the design of the rotary seal, the manufacturer tolerates
a certain amount of leakage. If the leakage is in excess of the
limit rotary seal must be renewed.
Tolerated leakage:
For this check the engine must be operated until all temperatures have stabi-
lized for a period of 5 minutes. At that point shut down engine and ensure the
ignition is switched off and engine secured against unintentional operation.
Coolant must not drip through leakage bore, located at the base of the ignition
housing, for a period of 1 minute after the engine has been stopped.
In case this leakage test can not be passed, the rotary seal must be renewed.
Risk of severe burns and scalds!
WARNING
WARNUNG
Never open the radiator cap when the cooling system
is hot. For safety's sake, cover cap with a rag and open
slowly. Sudden opening of the cap could provoke the
escape of boiling coolant and result in scalding.
If the oil filter has been replaced, re-tighten by hand af-
WARNUNG
NOTICE
ter the trial run on a cold engine.
Procedure