Avoiding false alarms

SENSITIVITY
Header On
= HIGH)
1. Avoid placing the detector in direct sunlight.
2. Do not let pets and other animals wander freely whilst the alarm system is armed.
Header Off
3. Do not mount the detector near heaters or radiators.
= LOW
4. Do not mount the detector near open windows or air vents.
5. Mount the detector on a stable surface.
Changing the battery
The batteries supplied have been chosen to
provide long service life whilst, for safety
reasons, having limited output current.
Replace only with approved batteries.
WINDOW
To prevent possible damage to components,
any static charge on your body needs to be
eliminated before touching the inside of the
unit. This can be accomplished by touching
some grounded/earthed metallic conductor
such as a radiator/pipework immediately
Learning the MC1-WE to the Enforcer control panel
Example:
When you are ready to learn the device to the control panel receiving equipment, and when the
equipment is in the learn mode (see Enforcer Programming Manual) follow the procedure below.
1. Make sure the battery is installed correctly and the plastic wrapping removed.
2. Press and Hold the Learn button until the 3 LEDs start cycling through the different colours, then
release the Learn button.
3. The device is correctly learnt when the Green LED flashes.
The three coloured LEDs give a visual indication of the signal strength.
Green indicates good signal strength and is a good location to install.
Red indicates poor signal strength and the device should not be
installed in that position.
S1 Enable
T
If no LED illuminates then the device is completely out of range.
CR2 Battery
Learn
The blue LED will illuminate when the device is activated.
-
+
CR2 Battery
12m Wireless PIR Detector
Sensitivity Settings
Universal Transmitter
Z
T
T
C
Z
Test Result
If the battery needs to be replaced, the
correct battery type (CR2) must be
installed
-
Piro Sensor
DO NOT TOUCH
Using Magnetic Contact 1 (S1)
Door Frame
Door
REAR TAMPER
CR123A
+
LITHIUM
BATTERY
TAMPER
ZONE
Model:
Colour:
Casing:
Transmission Frequency:
Tranmission Method:
Transmission Range:
Detection Method:
Sensitivity:
Temperature Compensation:
Detection Range:
Detection Zones:
Detection Speed:
DetectionAngle:
Battery:
Battery Life:
Mounting Height:
Tamper Switch:
Storage Temperature:
Operating Temperature:
Accessories:
22
Emissions:
Immunity:
Learn Button
To enable Magnetic Contact 1 you must remove
jumper link from the S1 enable pins:
Reed Switch
S1
S1 Enable
Z
T
T
C
Z
-
Magnetic
Contact 1
Tamper
Zone
Enable/
Enable/
Enable/
Disable
Disable
Disable
+
S1
S1 Enable
Z
T
T
C
Z
®
KX12DW 12m Internal detector
WHITE
3mmABS, 0.4mm HDPE in LensArea
868MHz, FMTransceiver Narrow Band
Fully Encrypted Rolling Code
300m Free Space
Low Noise Pyroelectric Sensor
High, Low
RED
AdvancedAutomatic
12m
74
RED
0.3 - 3.0 m/s
85
RED
CR123A Lithium Battery
Greater than 2 years
1.8m to 2.4m
RED
Front + Optional RearTamper
-20 C to 50 C
-10 C to 50 C
RED
Wall and ceiling mounting brackets optional
EN55022 Class B
EN50130-4
Test Result
Learn
S2 Enable
Status LEDs
CR123A
-
LITHIUM
BATTERY
Test Result
Learn
Learn
Button
BLUE GREEN
BLUE GREEN
BLUE GREEN
BLUE GREEN
BLUE GREEN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents