Mc1-We; Technical Specifications - Pyronix Enforcer 32WE Setup Manual

Hide thumbs Also See for Enforcer 32WE:
Table of Contents

Advertisement

+

MC1-WE

Technical Specifications

Model:
Colour:
Casing:
Transmission Frequency:
Transmission Method:
Transmission Range:
Indication:
Reed Switch:
Detection Points:
Detection Inputs:
Battery:
Battery Life:
Tamper Switch:
Storage Temperature:
Operating Temperature:
Rear Tamper Switch
There is a rear wall tamper protection switch at the
back of the MC1-WE device.
This tamper protection switch prevents the device
from being removed from its installed location and
prevents the lid from being removed.
Detection point
The MC1-WE has a detection point:
The example below shows how you can use them on an entry door:
Using Magnetic Contact 1 (S1)
Door Frame
-
CR2 Battery
Wireless magnetic contact/universal transmitter
with 1 reed, 1 input & tamper
MC1-WE
WHITE
3mm ABS, 0.4mm HDPE in Lens Area
868MHz, FM Transceiver Narrow Band
Fully Encrypted Rolling Code
300m Free Space
Three LED Combinations
(RSSI, Battery Status and Alarm)
1 x MC1-WE
2, Side and End
1 External Input & 1 External Tamper Input
3.6V 2.2Ahr AA Lithium Battery
Up to 2 Years
Front + Optional Rear Tamper
-20°C to 50°C
-10°C to 50°C
To enable Magnetic Contact 1 you must remove the
jumper link from the S1 enable pins:
Reed Switch
Door
S1
Z
T
C
Z
Tamper
Zone
installed
Tamper Switch
Magnet
Contact
Test Result
S1 Enable
T
Door
Learn
S2 Enable
Contact
/ Sensor
17
Magnetic
Contact 1
Enable/
Back view of the MC1-WE
WINDOW
U
Example:

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents