Learning Contacts & Detectors
It is recommended that all detectors, door contacts or
smoke detectors are learnt at the Enforcer before any
installation/mounting is done. This makes learning
much quicker.
A maximum of 32 wireless inputs may be learnt.
Even though the 'learn' may be successful, the
position of the input in a property must be tested for
signal strength before it is actually 'fixed' into place.
Please see page 13 when analysing the wireless
range and signal strength.
Before learning each input (detector or door contact)
check that the battery is present and inserted
correctly.
Follow the instructions on the right to start learning
the inputs.
An input that is learnt correctly will flash the GREEN
LED briefly and 'Input Learnt' will be displayed on
the keypad. Both of these instances need to occur to
indicate a successful learn.
Once learning has completed, each input needs to be
given a type (final exit, intruder,etc.) please see the
main programming manual (Change Inputs) for more
information.
,
1
/
2
A
3
D
A
+
B
E
.
C
F
4
G
5
J
6
M
B
H
K
N
I
L
O
P
W
7
8
T
9
C
Q
U
X
R
Y
V
S
Z
0
D
SPACE
,
1
2
A
3
D
A
/
+
B
E
C
F
.
4
G
5
J
6
M
B
H
K
N
I
L
O
P
T
W
7
Q
8
9
X
C
U
R
V
Y
S
Z
0
D
BYP
SPACE
Red Blue Green
BYP
9
Use b and x to scroll to:
RADIO DEVICE
CONTROL?
Press t
Control Inputs?
Press t
Learn Devices?
Press t
Input 01
Available
[01]
Input 02
Learnt
Enter Input. Press t
If 'learnt' is displayed
on an input, this will
need to be deleted
before learning can
begin. See page 12
for deleting inputs.
Learning...
When 'Learning' is
displayed, press and
hold the 'LEARN'
button on the device
until the LEDs cycle,
then release.
Input Learnt
Input Learnt
Already!
If the input device has
already been learnt to
the Enforcer system,
'Input Learnt Already!'
will be displayed.
Press t
[02]
Need help?
Do you have a question about the Enforcer 32WE and is the answer not in the manual?
Questions and answers