Bit
0
1
2
3
4
5
6
7
16.7.1.3.2 Detailed Discussions of Bit 3
iR1020J / iR1024J / iR1020 / iR1024 / iR1024A / iR1024N / iR1024F / iR1024i / iR1024iF
Select whether split recording is to be enabled when text data such as a header and body text is recorded. Selecting "Set" may split text data when a small paper size
such as A5 is selected. In this case, a page may be split in the middle of a character string.

16.7.2 Numerin Parameter Settings (Numeric Prama.)

16.7.2.1 Numeric Parameter Functional configuration

iR1020J / iR1024J / iR1020 / iR1024 / iR1024A / iR1024N / iR1024F / iR1024i / iR1024iF
No.
01: - 30:
31:
32:
33:
34:
35:
36:
37: - 38:
39:
40:
41:
42:
43: - 50:
51:
52:
53:
54:
55:
56:
16.7.2.2 <031: Top registration adjustment (manual feed tray)>
iR1020J / iR1024J / iR1020 / iR1024 / iR1024A / iR1024N / iR1024F / iR1024i / iR1024iF
Adjust the top registration margin of paper picked from a manual feed tray. The larger the adjustment value, the wider the top margin of the image becomes.
16.7.2.3 <032: Top registration adjustment (cassette)>
iR1020J / iR1024J / iR1020 / iR1024 / iR1024A / iR1024N / iR1024F / iR1024i / iR1024iF
Function
Not used
Not used
Not used
IFAX Permission of split recording of text data
Not used
Not used
Not used
Not used
Function
Not used
Top registration adjustment (manual feed tray)
Top registration adjustment (cassette)
Top registration adjustment (duplex unit)
Left-end registration adjustment (manual feed tray)
Left-end registration adjustment (cassette)
Left-end registration adjustment (option cassette)
Not used
Left-end registration adjustment (duplex unit)
Target fixing temperature adjustment (multi)
Target fixing temperature adjustment (cassette)
Target fixing temperature adjustment (option cassette)
Not used
Two-sided curl reform mode
Not used
Adjustment of margin at leading edge of copy
Adjustment of margin at trailing edge of copy
Adjustment of margin at right edge of copy
Adjustment of margin at left edge of copy
T-16-19
1
-
-
-
Enable
-
-
-
-
Default
50
50
50
100
100
100
100
2
2
2
3
0
50
0
0
0
-
-
-
Disable
-
-
-
-
Setting range
0 to 100, one unit = 0.1 mm
0 to 100, one unit = 0.1 mm
0 to 100, one unit = 0.1 mm
0 to 200, one unit = 0.1 mm
0 to 200, one unit = 0.1 mm
0 to 200, one unit = 0.1 mm
0 to 200, one unit = 0.1 mm
0 to 4, one unit = 5 deg C
0 to 4, one unit = 5 deg C
0 to 4, one unit = 5 deg C
0 to 6, one unit = 5 deg C
0 to 9999, one unit = 5 deg C
0 to 9999, one unit = 5 deg C
0 to 9999, one unit = 5 deg C
0 to 9999, one unit = 5 deg C
Chapter 16
0013-1388
0013-1389
0013-1390
0013-1391
16-27