Parts counter list
Item
DRBL-1 (Unit supplies)

16.12.2 Clearing Counters

iR1020J / iR1024J / iR1020 / iR1024 / iR1024A / iR1024N / iR1024F / iR1024i / iR1024iF
- Maintenance/parts counter all clear
Execute service mode > CLEAR > COUNTER to clear all maintenance/parts counters.
- Counter clear on parts replacement
Press the numeric keypad key 0 after displaying the counter for a part just replaced, and the counter will be cleared individually.
T-16-23
Counter
Explanation
PT-DRM
Drum unit rotation count
Chapter 16
Service life
26,000
0013-1410
16-31