Num (Numeric Parameter Setting Mode) - Canon imageCLASS MF269dw Service Manual

Hide thumbs Also See for imageCLASS MF269dw:
Table of Contents

Advertisement

NUM (Numeric parameter setting mode)

No.
001
Not used
002
RTN transmission condition X
003
RTN transmission condition n
004
RTN transmission condition m
005
NCC pause time (before ID code)
006
NCC pause time (after ID code)
007
Not used
008
Waiting time after dialing in STORED_DIAL_MODE
009
Not used
010
T.30 T0 timer
011
T.30 T1 timer (for reception)
012
The maximum number of received lines
013
T.30 EOL timer
014
Not used
015
Threshold between hooking and on-hook
016
Time until a primary response is obtained when switch-
ing FAX/TEL
017
Pseudo RBT cadence ON time
018
Pseudo RBT cadence OFF time (short)
019
Pseudo RBT cadence OFF time (long)
020
Pseudo RBT cadence ON time
021
Pseudo CI cadence OFF time (short)
022
Pseudo CI cadence OFF time (long)
023
Not used
024
Not used
025
CNG monitor duration while the answering device is ac-
tivated
026
Not used
027
Not used
028
Not used
029
Pseudo CI DUTY setting (setting can be made with
SPL71100 in special management mode.)
030
Not used
031
Not used
032
Not used
033
Not used
034
Not used
035
Not used
036
Not used
037
Not used
038
Not used
039
Not used
040
Not used
041
Not used
042
Not used
043
Not used
044
Not used
045
Not used
046
Not used
Parameter
269
Possible setting range
-
1 to 99 %
2 to 99 times
1 to 99 lines
1 to 60 sec
1 to 60 sec
-
0 to 65 sec
-
0 to 9,999
(55 sec in principle: 5,500)
0 to 9,999
(France: 3,500, Others: 3,000)
0 to 65,535 lines
(Unlimited in the case of 0)
500 to 3,000
(Default 13 sec: 1,300)
-
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
-
-
0 to 999
-
-
-
1 to 99
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-