BTG 9.0 KW SYSTEM SPECIFICATIONS
AC GENERATOR
General
Voltage
Rating (volts AC)
60 Hertz (1800 rpm)
50 Hertz (1500 rpm)
Generator Cooling
Air Requirements, (60 hertz), .
at 1800 rpm
Brushless, four-pole, revolving field.
Pre-lubricated, single-bearing design.
Reconnectable, single-phase transformer regulation
(optional solid-state voltage regulation).
120 or 120/240 volts - 60 hertz
220 volts - 50 hertz.
Voltage regulation: ±5% no-load to
full-load.
Frequency regulation:
±
3 hertz (5%)
no-load to full-load.
120 volts
120/240 volts
220 volts
75 amps
75/37.5 amps
29 amps
225 - 250 cfm (6.37 - 7.08 cmm)
NOTE: Increase generator cooling air supply 15% for 50 hertz operation (1500 rpm).
Engine Combustion Air
Requirements, (60 hertz),
at 1800 rpm
TUNE-UP SPECIFICATIONS
Spark Plug Gap
Contact Point Clearance
Dwell Angle
Condenser Capacity
Timing
Westerbeke Generators
34 cfm (0.96 cmm)
0.028 - 0.036 inches (0.7 - 0.9 mm)
0.016 - 0.020 inches (0.4 - 0.5 mm)
.225 - .275 microfarads (uF)
11
0
±
1
0
BTDC at 1800 rpm
10
0
±
1
0
BTDC at idle speed (900 rpm)
50