Shore Power Connections
If the installer connects shore power into the vessel's AC circuit, this must be done by means of the SHORE
POWER/OFF/SHIPS GEN., center position-off transfer switch as shown below.
CAUTION
Damage to the generator can result if utility shore power and generator output are connected
at the same time. This type of generator damage is not covered under the warranty; it is the
installer's responsibility to ensure that all AC connections are correct.
~ator
MOTE: DIAGRAM SHOWS CONNECTIONS FOR TWO-
lNG' G2
WIRE.
128-UOLT SYSTEM. FOR THREE-WIRE
t
=-L ______
Sy_ST...,EM USE DOTTED LINES FOR THE
i
z
OTHER HOT LEGS.
1
I
/~--
. . . . .
L ____ -f-(j)
~\
I
01-_
- - - ,
r-----\~;'
I
I
, __ ....
I
1
I
I
I
I
I
..... --,
I
~rl-I--~(;
__ ""' )
i
I ·
, ' - - - \
~-~lShiP.'
1
t
' ~ - . . > : G - , " , , " : ; " " : " - : -
_ __ -tll.
LOAD
\ S2 SI, N
Shore Power
SHIP-TO-SHORE SNIlCH
13
POL£)
PM 32118
148 AMPS/POLE!
PN
32119
III AMPS/POLE!
PN
32811
1125 AMPS/POLE]
PM
32133
1288 AMPS/POLE]
GeneraTor
NOTE: DIAGRAM SHOWS CONNECTIONS FOR A TWO-
WIRE, 121-VOLT SYSTEM FROM THE GENERATOR,
.
( N
Gl
-
WITH THREE-WIRE, 121-UOLT
L--_ _ _ _
--=B:.::O~A..:..T
...;SYSTEM.
Ship. t o-Shore
Switch (3 Pole)
L2
Shp·SLoad
Note
NO 24()'VOIt
equipment
Shore Power Switch Connection Diagram
27
PH 32BBB
(48 AMPS/POLE)
PM 32889
(sa
AMPS/POLE)
PM 32811i1
(125 AMPS/POLE]
PH 32133
(288 AMPS/POLE]
Westerbeke Generators