4. Measure the rotor shaft's clearance. If it has worn
beyond the allowable limit, replace the rotor and
the rotor housing.
Specified Limit:
0.0018 - 0.0033
inches
(0.045 - 0.085
mm)
Allowable Limit:
0.0039
inches
(0.10
mm)
5.
Measure the tip clearance.
Specified Limit:
0.0059
inches
(0.15
mm) or less
Allowable Limit:
0.0079
inches
(0.20
mm)
6.
Measure side clearance.
Specified Limit:
0.0012 - 0.0035
inches
(0.03 - 0.09
mm)
Allowable Limit:
0.0079
inches
(0.20
mm)
111
Westerbeke Generators