Westerbeke 9.0 BCG Technical Manual page 220

Marine gasoline generators
Table of Contents

Advertisement

FAULT
Correct no-load voltage,
but high voltage output when
load applied.
Unstable voltage output.
CAUSE
Engine speed is
too fast.
1. Poor governor
reaction.
2. Loose electrical
connections.
IIWARNINGI
CORRECTION
Adjust hunting/regulation
on the governor.
Adjust to proper no-load
voltage hertz.
1. Adjust hunting/regulation
on the belt-clriven governor.
2. Check the security and
cleanliness of electrical
connections.
Stop the generator before checking the connections.
Noisy generator.
Westerbeke Generators
1. Unbalanced load
(120/240 wired).
2. Rear support bearing
is faulty.
3. Generator connection
to engine is loose.
214
1. Check each load as it is
taken off each 120 volt
leg with an amp-probe.
2. Check each load as it is
taken off each 120 volt
leg with an amp-probe.
3. Stop the generator
and check the
connection.

Advertisement