Electrical Components - MV Agusta Brutale 675 Workshop Manual

Hide thumbs Also See for Brutale 675:
Table of Contents

Advertisement

ELECTRICAL COMPONENTS

BATTERY CHARGING SYSTEM
Battery warning light on
POWER SUPPLY FOR 12V SERVICES
No function enabled
ELECTRIC STARTER
Electric starter does not work
COOLING SYSTEM
Electric fan do not work
LIGHTS/INDICATORS
Position lights not working
O
High beam does not work
Diagnostic
Check the condition of the fuse on the remote switch
Faulty fuse connection on remote switch
Faulty remote switch connection
Battery connection defective
Battery faulty
Alternator broken
Alternator connection defective
Check the condition of the fuse on the remote switch
Ignition switch broken
Ignition switch connection defective
Main relay broken
Main relay connection defective
Check condition of fuse 5
Fuse 5 connection faulty
Faulty engine earth connection
Faulty power cable connection
Faulty battery power cable connection
Faulty or dead battery
'On off' button on right switch on 'off'
Right-hand switch faulty
Right-hand switch unit connection faulty
Starting relay broken
Starting relay connection faulty
Starter motor broken
Faulty starter cable connection
Clutch pump switch broken
Faulty clutch switch connection
Fall detection sensor failure
Faulty fall detection sensor connection
Side stand switch failure
Faulty side stand switch connection
Check condition of fuse 5
Fuse 5 connection faulty
Electric fan broken
Electric fan connection faulty
Check condition of fuse 7
Fuse 7 connection faulty
Failure of the water sensor in the radiator
Faulty connection for water sensor in the radiator
Fan relay connection faulty
Fan relay broken
ECU failure
Faulty ECU connection
Front light failure
Faulty front light connection
Tail light failure
Faulty front light connection
Check condition of fuse 3
Fuse 3 connection faulty
Ignition switch broken
Ignition switch connection faulty
Bulb burnt out
Bulb connection faulty
Faulty front light connection
Check condition of fuse 4
Fuse 4 connection faulty
Lights switch broken
Lights switch connection faulty
- 2 -
Replace
Deoxidize/Repair
Deoxidize/Repair
Deoxidize/Repair
Replace
Replace
Deoxidize/Repair
Replace
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Deoxidize/Repair
Deoxidize/Repair
Deoxidize/Repair
Replace
Turn on
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Deoxidize/Repair
Replace
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Deoxidize/Repair
Deoxidize/Repair
Replace
Deoxidize/Repair
Replace
Replace

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brutale 800Dragster 800

Table of Contents