Close the loading hole with the screw-on cap and tight-
en it at the prescribed tightening torque.
Torque pressure: 7 ÷ 8 N·m
Start the engine, keeping it running long enough to
heat the fluid until the cooling fan begin operating, then
turn the engine off. Repeat the operation at least once,
then wait a few minutes for the engine to cool.
Check thoroughly for leaks, seepage, dam-
aged pipes, etc in the cooling system. If nec-
essary overhaul the system following the
steps described in this chapter.
L
Check the coolant liquid level inside the expansion
tank again. It must be above the "MIN" level marking
on the expansion tank.
If the level is below the "MIN" mark, top it up by adding
new liquid through the fill cap.
Cooling system
- 36 -
7 ÷ 8 N•m
Min. level