Install the Touch Panel Controller (TPC)

1. Loosen the mounting arm just enough for the end to fit over the ball joint located on the rear
panel of the projector.
2. Tighten the mounting arm until it fits tightly on the joint.
3. Connect the cable from the TPC to the connector on the rear panel of the projector.
4. Adjust the TPC angle for optimal viewing.

Connect External Exhaust Ducting

At minimum, a 10-inch (25.4 cm) long, strong metal duct must be installed at the projector
and installed to an outside venting duct system to prevent glass shards from exiting the duct
in the event of a lamp explosion. Failure to comply could result in death or serious injury.
*600 CFM is required in projection rooms with an ambient temperature above 25°C or
located at an elevation greater than 3000 feet above sea level. Failure to comply may result
in equipment damage.
Connect the existing outside-venting duct to the 8-inch
diameter exhaust port on the top of the projector. Make sure
there are no obstructions or bends in the ducting or air intakes
and the vane switch at the exit duct moves freely.
The pre-installed outside-venting duct should be rigid at the
projector and must also include a heat extractor and blower
that maintains a minimum of 450 CFM* when the projector is
operating at less than or equal to 25°C (77°F) ambient and less
than 3,000 feet (914.4 m), when measured at the projector
exhaust opening.
To determine the projector exhaust CFM value, use an airflow
meter to measure the ft/min at the rigid end of the open
14