This section explains how to install, connect and optimize the projector display.

Site Requirements

To safely install and operate the D4K2560 projector, the installation location must meet these
minimum requirements:
Physical Operating Environment
Maximum Ambient Temperature (operating) 35°C (95°F)
Minimum Ambient Temperature (operating) 10°C (50°F)
External Exhaust Ducting
The installation site must provide a minimum of 450 CFM (ft 3/min) external exhaust airflow to
ensure adequate cooling of the Xenon arc lamp at less than or equal to 25°C (77°F) ambient and less
than 3,000 ft (914.4 m) elevation. Above 25°C or 3,000 ft, 600 CFM is required. For CFM measuring
instructions, see
Connect External Exhaust Ducting
Power Connection
The requirements listed below are applicable for permanently wired installation or power
cord connection.
Terminal block, electrician hard-wired to the projector head.
Electrical rating: 200 - 240 VAC, 23 A max.
This product can be connected to an IT power distribution system.

Tools Required for Installation

12" screwdrivers: Phillips #2 (magnetic) and flat
19mm and 7/8" wrenches
Assorted Allen keys (metric)
Christie approved protective safety clothing if working with the lamp
Lens cleaning tissue and solution