Troubleshooting
Flicker, Shadows Or Dimness
•
Make sure the shutter is fully open.
•
Verify that a LampLOC calibration is not already in progress.
•
Perform LampLOC calibration.
•
Increase the lamp power. Lamps which are near end of service may not operate reliably at a
lower power setting.
•
Fold mirror misalignment. Contact your Christie accredited service technician.
•
Integrator rod misalignment. Contact your Christie accredited service technician.
LampLOC Not Working
•
If the Auto LampLOC option is not working, tap Menu Tab > Lamp > LampLOC and adjust
the lamp position manually. Observe screen brightness by adjusting the X, Y and Z values or use
a light meter to check for changes in brightness.
•
Check that the flat part of the anode end of the lamp (if applicable) faces up in the anode yoke.
Touch Panel Controller (TPC)
•
If the TPC display is blank, make sure the TPC communication harness is connected securely.
Blank Screen, No Display of Image
•
Make sure both lens caps have been removed from the projection lens.
•
Make sure the lamp is ON.
•
Make sure that all power connections are OK.
•
Make sure the shutter is fully OPEN.
•
Make sure that any test pattern (other than a full black test pattern) displays properly.
Cannot Communicate with Projector
•
Make sure the computer and the projector are both connected to the network.
•
Make sure that all input devices have the same subnet mask and unique IP addresses.
38
D4K2560 User Manual
020-101076-01 Rev. 1 (06-2013)