Print Reports At Specified Time (Pset); Error Log Display (Elog) - Panasonic KX-TVP100E Installation Manual And Instructions For Use

Voice processing system
Hide thumbs Also See for KX-TVP100E:
Table of Contents

Advertisement

7.1
Utility Commands
3
Enter the current date.
For the year, type the last two digits.
Note:

7.1.5 Print Reports at Specified Time (PSET)

If a printer or a data terminal is connected to the VPS via the RS-232C port, you
can issue the following system reports at the specified time everyday by entering
PSET command.
Disk Usage Report / Port Usage Report / Call Account Report
1
Type "PSET", then press [RETURN].
$ PSET
Report Print Out Service [ Disable ]
1: Enable 2: Disable :=
2
Press [1] to activate this function.
Press [2] to deactivate it.
Enter The Print Out Time (HH:MM, AM/PM) :=
Enter the time to print the report.

7.1.6 Error Log Display (ELOG)

You can diagnose the VPS by getting the error log of devices such as the CPU card,
Port cards and the hard disk.
COM.
DATA
MEM.
PRG.
R/W
Enter the exact time and date so that the VPS will function correctly.
This command is invalid while the System Manager or the Message
Manager is accessing the time setting feature.
or
Communication error between CPU and Port cards
Process error of voice data
Memory error
Program error in CPU card
Read/Write error of hard disk
7-5
Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents