7.10.2: Wireless Siren Delay
The Wireless Siren Delay is the period of time during which the wireless siren is not
sounded after an alarm is triggered by normal, follower or 24Hr zones. This feature is
implemented only when the system is not fully armed. During the Wireless Siren Delay,
the control system's built-in siren is sounded but the alarm report is not sent until the
delay has expired. This gives the user enough time to disarm in the event that the alarm
was accidentally triggered during Part or Perimeter arming. If the user disarms the
system during the Siren Delay, an alarm event is not reported to the central station.
To program the Wireless Siren Delay time:
1.
From the Programming menu, select Devices, Siren, WL Siren Delay [9153].
2.
Enter a Siren Delay time (00-63 seconds).
3.
Press
when the desired setting is displayed.
7.10.3: Siren Cut-Off
The Siren Cut-Off is the period of time the sirens are activated after an alarm has occurred.
You may program a Siren Cut-Off time of between ten seconds to twenty minutes.
To program the Siren Cut-Off time:
1.
From the Programming menu, select Devices, Siren, Cut-Off [9154].
2.
Enter a Siren Cut-Off time (00:10 - 20:00).
3.
Press
when the desired setting is displayed.
7.10.4: Wired Siren
When the system generates an audible alarm, both the wired built-in siren and the
wireless siren are sounded. This option allows you to disable the alarm from the control
system's built-in siren. If disabled, the control system's built-in siren may still be used to
sound arm/disarm and entry/exit tones.
To program the Wired Siren option:
1.
From the Programming menu, select Devices, Wired Siren [9155].
2.
Select Enabled or Disabled.

7.11: Smartkeys

Smartkeys enable the user to arm and disarm the system without needing to enter a
code. You can register up to 16 smartkeys to the system. For information on registration,
descriptor editing and deletion, see 7.1: Device Registration, 7.2: Device Descriptors and
7.3: Device Deletion, respectively.
7.11.1: Smartkey Type
You can define each registered smartkey as Controlled or Non-controlled. A Controlled
smartkey causes the system to send arm/disarm event messages to the central station.
Non-controlled smartkeys never send arm messages and send a disarm message only if
the system is disarmed after an alarm occurrence.
To program the smartkey type:
1.
From the Programming menu, select Devices, Smartkeys [918].
2.
Select the smartkey you want to program.
3.
From the smartkey's sub-menu, select Type [#2]; the current
setting is displayed.
4.
Select either Controlled or Non-controlled.
-52-