To partially arm the system using the hardwire LCD keypad:
1.
Check if the system is ready to arm.
2.
Press PART on the keypad.
3.
Select Part arming.
4.
If One-Key Arming is disabled, enter your user code.
3.7.4: Perimeter Arming
Perimeter arming is designed for when the occupant intends to remain inside the
premises and secure the perimeter.
To arm the system's perimeter using the front panel keypad:
1.
Check if the system is ready to arm.
2.
Press the Perimeter arming key on the keypad.
3.
If One-Key Arming is disabled, enter your user code.
To arm the system's perimeter using the hardwire LCD keypad:
1.
Check if the system is ready to arm.
2.
Press PART on the keypad
3.
Select Perimeter arming.
4.
If One-Key Arming is disabled, enter your user code.
3.7.5: Combination Arming
The system allows you to activate a combination of two arming modes. If you Perimeter
arm the system, you may also activate Full or Part arming. Likewise, you can Perimeter
arm the system after activating Full or Part arming. It is not important which arming mode
you choose first.
You can activate the second arming mode during the exit delay of the first arming mode.
If the first exit delay expires, you cannot activate a second arming mode.
To arm the system using two arming modes:
1.
Check if the system is ready to arm.
2.
Activate the first arming mode.
3.
If One-Key Arming is disabled, enter your user code.
4.
While the exit delay of the first arming mode is counting down, activate
the second arming mode.
5.
If One-Key Arming is disabled, enter your user code.
It is not possible to activate Full and Part arming modes simultaneously.
It is necessary to disarm first when changing from one arming mode to another arming mode.
The exit delays of the two arming modes are entirely independent. The moment an arming
mode is activated, its exit delay begins to count down. The entry delay depends on which
sensor was tripped first. For example, if the sensor is included in Full arming, the entry
delay for Full arming counts down – see 7.6.2: Arm Set. If the sensor is included in both
activated arming modes, the entry delay for Perimeter arming counts down.
If, due to open zones, the system is not ready to activate the second arming mode then
both arming methods are canceled. In this case, check that the relevant entrances are
secured and start the entire arming sequence again.
Disarming cancels both active arming modes.