Mrw" Command - Caen ELS LiAM 6005 User Manual

Table of Contents

Advertisement

Remote Control

5.3.14 "MRW" Command

The 'MRW\r' command returns the actual value of the estimated active power
supplied to the connected load.
This estimation, being computed as the product of the output voltage and the
output current readback values, has also an 18-bit resolution and it is presented with a
5-digit precision.
Replies from the power supply LiAM controller to this command are in the
following form:
where:
 value is the output active power readback [W], estimated as the product of
output voltage and output current readbacks.
The MRW command, being a reading command, returns a response in any
module condition.
Examples:
MRW example when the module is OFF:
MRW\r
MRW example when the module is ON and regulating output current:
MRW\r
#MRW:value\r
LiAM User's Manual
#MRW:-0.00432\r
#MRW:+207.32445\r
68

Advertisement

Table of Contents
loading

Table of Contents