Commands Overview - Caen ELS LiAM 6005 User Manual

Table of Contents

Advertisement

LiAM User's Manual
MRG
MRI
MRID
MRM
MRP
MRN
MRR
MRT
MRV
MRW
MSP
MSR
MST
MTUNE
MUP
MWG
MWI
PASSWORD
VER
It is important to notice that some commands are write-only commands (e.g.
MWI to set output current) and some others are read-only commands (e.g. MRI to
read output current value).
The only command that allows reading and setting is the MSR command, which
reads or sets the user-defined slew-rate for the power supply (see 'MSR Command'
section for further details).

5.3 Commands Overview

The power supply controller replies every time that a termination character '\r'
is received. Replies could have different behaviors:
51
Read selected EEPROM "value" cell
Read output current value
Read module identification
Set output current value (ramp)
Read positive rail voltage value
Read negative rail voltage value
Read estimated resistance value
Read output stage maximum temperature
Read output voltage value
Read estimated active output power value
Read last stored output current setpoint
Read or write slew-rate value
Read module internal status register
Launch automatic load tuning procedure
Update all EEPROM parameters
Write selected EEPROM "value" cell
Set output current value (no ramp)
Write password to unlock password-
protected cells
Read module model and installed
firmware versions
: LiAM module command list
Table 6
Remote Control
R
R
R
W
R
R
R
R
R
R
R
R/W
R
W
W
W
W
W
R