Mrn" Command - Caen ELS LiAM 6005 User Manual

Table of Contents

Advertisement

Remote Control

5.3.10 "MRN" Command

The 'MRN\r' command returns the value of the negative power rail voltage, i.e.
negative DC Link. Readback values have a unipolar 12-bit resolution.
Replies from the LiAM power supply unit to this command are in the following
format:
where:
 value is the measured DC Link voltage [V].
Even if the internal ADC dedicated to this purpose has a 12-bit resolution, this
value is presented to the user only with a 100 mV resolution.
The MRN command, being a reading command, returns a response in any
module condition.
Examples:
MRN example when the rail voltages are disabled:
MRN\r
MRP example when the negative rail is at mid-level voltage:
MRN\r
#MRN:value\r
LiAM User's Manual
#MRN:0.0\r
#MRN:-53.6\r