5.3.3 "MON" Command

The 'MON\r' command is intended to turn on the LiAM output, thus enabling
the output current terminals and allowing the power supply to regulate and feed
current to the connected load.
After the reception of an 'MON\' command, the power supply automatically
sets output current to 0A (zero) when enabling the output.
Replies from the power supply to a 'MOFF\r' command are in the form
'#AK\r' – when the command is correctly executed - or '#NAK\r'. The '#NAK\r'
reply is obtained if:
 the LiAM unit is in a FAULT condition (it is necessary to reset the status
register after a generic fault condition in order to turn the power supply ON again
- see command 'MRESET\r').
 the module output is already ON.
Examples:
MON example when the bulk power supply is enabled (ON) and no fault conditions:
MON\r
MON example when the system is already ON:
MON\r
57
Remote Control
#AK\r
#NAK\r