Conversion from a floorstand model to a rack model
Ê Remove the bar (3).
I
The bar is no longer required.
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the operating panel module can be taken out simply,
turned through 90° to the left, and then be reinstalled.
Ê Remove the dummy covers from the drive cage (see
Ê Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ê Pull the operating panel module forward out of its mounting location until you
can pull the I2C cable, the ribbon cable and USB cable out of the operating
panel module. Remove the three cables.
Ê Remove the operating panel module.
Ê Turn the operating panel module through 90° to the left.
Figure 99: Installing the operating panel module
Ê Push the operating panel module halfway into the upper bay of the drive
cage.
2
Ê Connect the I
panel module.
Ê Now push the operating panel module fully into the upper bay of the drive
cage.
Ê Turn the drives removed beforehand through 90° to the left.
TX300 S4
C cable, the ribbon cable and USB cable to the operating
Options Guide
figure 21 on page
41).
111