Wsw28 (Function Setting 6) - Ricoh G157 Service Manual

Hide thumbs Also See for G157:
Table of Contents

Advertisement

MAINTENANCE MODE

WSW28 (Function setting 6)

Selector
No.
Transmission level of DTMF high-
1–3
band frequency signal
Transmission level of DTMF low-
4–6
band frequency signal
7, 8
Not used.
Selectors 1 through 6: Transmission level of DTMF high-/low-band frequency signal
These selectors are intended for the manufacturer who tests the machine for the
Standard. Never access them.
G157
CÓPIA NÃO CONTROLADA
Function
5-70
CÓPIA NÃO CONTROLADA
Setting and Specifications
No. 1. 2. 3.
0 0 0: 0 dB
0 0 1: +1 dB
0 1 0: +2 dB
0 1 1: +3 dB
1 0 0: 0 dB
1 0 1: -1 dB
1 1 0: -2 dB
1 1 1: -3 dB
No. 4. 5. 6.
0 0 0: 0 dB
0 0 1: +1 dB
0 1 0: +2 dB
0 1 1: +3 dB
1 0 0: 0 dB
1 0 1: -1 dB
1 1 0: -2 dB
1 1 1: -3 dB