Inverter Power Supply Failure - Xerox Paser 7400 Service Manual

Table of Contents

Advertisement

Inverter Power Supply Failure

Applicable Status Code:
Code I97:
Inverter hardware error
Initial Actions:
Cycle the printer's power.
If the problem persists follow the procedure below.
Troubleshooting Reference Table
Applicable Parts
Inverter Power Supply
Troubleshooting Procedure Table
Step Actions and Questions
1
Check the following for evidence of fault or
damage:
Inverter Power Cord
Inverter Power Supply
Is there any damage?
2
Check AC Power.
Is the AC voltage available at the outlet?
3
Check the Inverter connection.
Is the Inverter interface cable securely
connected at both ends?
4
Replace the Inverter Power Supply
(page 5-56).
Does the error persist?
General Troubleshooting
Wiring and Plug/Jack References
Options Map 3 Inverter Controller Board
Options Inverter Motors
Yes
Replace any
damaged parts.
Go to Step 3.
Go to Step 4.
Replace the Inverter
Control Board
(page 5-46).
No
Go to Step 2.
Advise customer.
Connect the
Inverter to the
Finisher.
Complete.