4. PERIODICAL MAINTENANCE PROCEDURE
7. Install the new fuser unit.
8. From the Menu, select [MAINTENANCE MENU] → [SUPPLIES] → [REPLACE] →
[FUSER UNIT] and execute this function to reset the fuser unit counter value.
For details, see "ADJUSTMENT/SETTING."
18
4. Open the fuser unit cover [1].
[1]
A0VDF2C516DA
5. Pull down two levers [1].
[1]
A0VDF2C517DA
6. Remove the fuser unit [1].
[1]
A0VDF2C518DA
Field Service Ver. 1.0 May 2010