Field Service Ver. 1.0 May 2010
4.3

Fusing section

4.3.1

Replacing the fuser unit

• The temperature gets high in the vicinity of the fuser unit. You may get
burned when you come into contact with the area. Before replacement
operations, make sure that more than 20 minutes have elapsed since the
main and sub power switches were turned off.
A. Periodically replacing parts/cycle
• Fuser unit: Every 100,000 counts (2P/J)
B. Procedure
1. Turn OFF the power switch, unplug the power cord from the power outlet, and let the
machine to stand idle for about 20 min.
[1]
[1]
4. PERIODICAL MAINTENANCE PROCEDURE
CAUTION
2. Open the right door [1].
A0VDF2C514DA
3. Open the eject cover [1].
A0VDF2C515DA
17