13E2: Engine Flash Rom Write Error; 13E3: Engine Flash Rom Device Fault; 13F0: Engine Control Failure; C002: Ram Error At Startup (Standard Memory) C003: Ram Error At Startup (Expanded Memory) - Konica Minolta bizhub C35P Service Manual

Hide thumbs Also See for bizhub C35P:
Table of Contents

Advertisement

13. MALFUNCTION CODE
13.3.21

13E2: Engine flash ROM write error

13.3.22

13E3: Engine flash ROM device fault

Print control board (PRCB)
Step
1
Rewrite the engine firmware.
2
Change PRCB.
13.3.23

13F0: Engine control failure

Print control board (PRCB)
Step
1
Reboot the main body.
13.3.24
C002: RAM error at startup (standard memory)
C003: RAM error at startup (expanded memory)
MFP board (MFPB)
Step
1
Reboot the main body.
2
Check connection state of the standard/
expanded memory and correct as neces-
sary.
3
Check the MFPB connector for proper con-
nection and correct as necessary.
4
Change the standard/expanded memory.
5
Change MFPB.
160
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 May 2010
WIRING DIAGRAM
Control signal
-
-
WIRING DIAGRAM
Control signal
-
Standard memory
Expanded memory
WIRING DIAGRAM
Control signal
-
-
-
-
-
Location (electri-
cal component)
-
-
Location (electri-
cal component)
-
Location (electri-
cal component)
-
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents