13. MALFUNCTION CODE
13.3.3

0018: Developing motor malfunction

Developing motor (M1)
Step
1
Check the connector between M1-PRCB
PJ11 for proper connection and correct as
necessary.
2
Check the M1 connector for proper drive
coupling and correct as necessary.
3
M1 operation check
4
Change M1.
5
Change PRCB.
13.3.4
004A: Cooling fan motor malfunction
Cooling fan motor (FM11)
Step
1
Check the connector between FM11-relay
CN29-PRCB PJ10 for proper connection
and correct as necessary.
2
Check the fan for possible overload and
correct as necessary.
3
FM11 operation check
4
Change FM11.
5
Change PRCB.
154
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 May 2010
Print control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ11-3 to 6
-
-
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
-
-
PRCB PJ10-5 (REM)
PRCB PJ10-7 (LOCK)
-
-
Location (electri-
cal component)
-
-
B-15
-
-
Location (electri-
cal component)
-
-
F-7
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents