Konica Minolta bizhub C35P Service Manual page 155

Hide thumbs Also See for bizhub C35P:
Table of Contents

Advertisement

10. SERVICE MODE
Two-way communication
Step
4
Inputting the ID code
1. Select [SERVICE MENU]→[CS REMOTE CARE]→[SERVICE ENGR ID].
2. Input the seven digits ID of the service engineer, and press the Menu/Select key.
See P.122
5
Setting the Center ID
1. Select [SERVICE MENU]→[CS REMOTE CARE]→[BASIC SETTING]→[CENTER ID].
2. Input the six digits ID of the CS Remote Care center, and press the Menu/Select key.
See P.123
6
Encryption setting
1. Select [SERVICE MENU]→[CS REMOTE CARE]→[BASIC SETTING]→[ENCRYPTION].
2. Select [YES] or [NO] according to the necessity of encryption, and touch [OK].
7
Heart Beat *1
1. Select [SERVICE MENU]→[CS REMOTE CARE]→[CSRC SETTING]→[HEARTBEAT SET-
TING].
2. In [ENABLE HEARTBEAT], set whether or not to enable Heart Beat communication.
(Default: YES)
3. Select [INTERVAL] and enter a Heart Beat transmission interval (1 to 256 minutes, Default: 30
minutes).
4. In [ENABLE FIXED TIME], set whether or not to enable Heartbeat transmission at a fixed
interval. (Default: YES)
5. Select [FIXED TIME] and enter a Heartbeat transmission interval (1 to 256 minutes, Default:
30 minutes).
8
Proceed to step 10.
9
120
Field Service Ver. 1.0 May 2010
One-way communication
Procedure
Periodic transmission setting
1. Select [SERVICE MENU]→[CS REMOTE
CARE]→[CSRC SETTING]→[PERIODIC
TRANS.].
2. In [ENABLE TRANS.], set whether or not to
enable periodic transmission.
(Default: ON)
3. Select [INTERVAL], [TIME], [DAY OF THE
WEEK] or [DATE] and set the schedule of
periodic transmission.
See P.126
Report setting
1. Select [SERVICE MENU]→[CS REMOTE
CARE]→[CSRC SETTING]→[REPORT
SETTINGS].
2. Select the report item and set items that will
be reported to the Center.
See P.126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents