17. IGNITION SYSTEM

A .C. GENERATOR INSPECTION

EXCITER COIL/PULSER COIL
INSPECTION
This test is performed with the stator
installed in the engine.
Remove the seat and met-in box. ( Ö 2-6)
Disconnect the A.C. generator connector.
Measure the exciter coil resistance between
the black/white wire terminal and ground.
Black/white Ground
Measure the resistance in the X: range.
Electric tester: YF-3501
For A.C. generator removal/installation, refer
to pages 10-3 and 10-6.
Disconnect the pulser coil wire coupler.
Measure the pulser coil resistance between
the blue/white and green/white wire terminals.
Blue/Yellow Green/White
Electric tester: YF-3501
IGNITION UNIT
RESISTANCE INSPECTION
Measure the resistance between the
terminals.
Replace the ignition unit if the readings are
not within the specifications in the table
below.
8.1M:
105 110:
Pulser Coil Wire Coupler
Ignition Unit
PEOPLE/PEOPLE S 250
17-4